Salutron HardyTest HARTIP 1800 Operation Manual Download Page 13

 

11 

 

 

Change value or digit circulative from 0 to 9. 

 

Shift normal or upright display mode. 

Confirmation button:   

 

Enter main menu. 

 

Confirm the selected item. 

▼&▲

Press downward and upward button simultaneously: 

 

In measuring mode, turn off Bluetooth connection. 

6.4.2.

 

Impact Device 

This  tester  is  equipped  with  internal  D probe.  The  internal  impact  device  can  work  as 

standard  probe  when  using impact  body  D,  it can  also  work  as  special  probe  DL  when 

using impact body DL. Please set up Impact device to D while you are using probe D and 

set up Impact device to DL while you are using probe DL. 
 

 

Figure 6-6 Impact Device Selection 

After selecting impact device, “Successfully” will be displayed on the screen, then return 

to the Parameters menu. 

 

Figure 6-7 Measuring mode with impact device D 

 

 

Figure 6-8 Measuring mode with impact device DL 

6.4.3.

 

Materials selection 

Material  to  be  tested is  prior  to  hardness  scale.  In  another  word,  the material  must  be 

selected properly when you want to have any hardness scale except HLD. 

Choose 

Materials

  from  parameters  menu  and  press 

  button  to  enter  sub-menu.  11 

materials will be showed in following three screens. Press

 or 

 button to move among 

the  different  materials.  Then  press 

  button  to  confirm  it  and  return  to  parameters 

menu. 

Summary of Contents for HardyTest HARTIP 1800

Page 1: ...HARDNESS TESTER HardyTest HARTIP 1800 OPERATION MANUAL...

Page 2: ......

Page 3: ...SAMPLE OF CURVING SURFACE 7 5 6 SUPPORTING THE SAMPLES DURING TESTING 7 5 7 SAMPLES WITH CURVED SURFACES 7 6 OPERATION 8 6 1 BUTTON DESCRIPTION 8 6 2 DIAGRAM OF OPERATION 9 6 3 POWER ON THE INSTRUMEN...

Page 4: ...ional to the velocities of the magnet Leeb hardness is expressed by the following formula 1000 Vi Vr HL Where HL is Leeb Hardness Vr is the rebound velocity of the impact body Vi is the impact velocit...

Page 5: ...l probes With this optional accessory you can take measurement at very narrow surface such as slot bottom gear tooth that probe D cannot match The 3 7V Li ion rechargeable battery inside the tester ca...

Page 6: ...Recalibration allowed by user 2 4 Applications Hardness tests on installed machines or steel structures e g on heavy and large work piece or on permanently installed system parts Rapid testing of mult...

Page 7: ...MATERIALS H R C H R B H B H V H S HRA b N mm2 STEEL CAST STEEL 20 0 67 9 59 6 99 5 80 647 80 940 32 5 99 5 30 88 375 1710 ALLOY TOOL STEEL 20 5 67 1 80 898 1170 2639 STAINLESS STEEL 19 6 62 4 46 5 101...

Page 8: ...direction of impact should be perpendicular to the coupling surface For the coupling operation the following prerequisites must be fulfilled The contact surface of the sample and the surface of the b...

Page 9: ...be checked in the following manner a Medium weight samples and also heavier samples with protruding parts or thin walls should be placed on a solid support in such a manner that they do not move or fl...

Page 10: ...start to print a new page while Bluetooth printing is on Delete current reading after set up statistics Upward button Move cursor upward Change value or digit circulative from 0 to 9 Shift normal or u...

Page 11: ...9 6 2 Diagram of Operation Figure 6 2 Diagram of Operation...

Page 12: ...s required press the confirmation button on the keyboard to enter main menu Figure 6 4 Main Menu After entering main menu press or button to move among the different options press button to enter conf...

Page 13: ...t up Impact device to DL while you are using probe DL Figure 6 6 Impact Device Selection After selecting impact device Successfully will be displayed on the screen then return to the Parameters menu F...

Page 14: ...Different hardness scales will show on the screen depending on different materials The default hardness scale is Leeb hardness value HLD Figure 6 10 Hardness Scale 6 4 5 Impact Direction Choose Impact...

Page 15: ...tatistics menu and press button to enter sub menu Then press or button to choose different mean times then press button to confirm the selection and return to statistics Menu The default mean time is...

Page 16: ...s button to confirm the selection and return to statistics menu The default value of upper limit alarm is 999 HLD When the users set the value of upper limit alarm the ranges of hardness values corres...

Page 17: ...t as any block of existing blocks Press button to move the cursor and choose the value of modified group No cycling from hundreds tens units to return in turn When the cursor is moved to the option of...

Page 18: ...window All blocks stored in the instrument are showed on the interface At most 9 block numbers are showed on each screen Change Page is showed on upper left corner Displayed content can be changed by...

Page 19: ...irm Figure 6 24 Communicating by USB RS232 Figure 6 25 Communicating by Bluetooth Via USB RS232 or Bluetooth interface testing values can be downloaded to PC or printed by micro printer with our speci...

Page 20: ...nsferring on line Start software on PC and operate the relative tool to download the data from memory Note Please make sure the connection between PC and tester is successful See 11 3 6 7 4 Print bloc...

Page 21: ...s hardness scale Under Bluetooth communication mode pressing button In order to meet the measurement of requiring different direction it is also designed to change display direction which function can...

Page 22: ...apacity and storage capacity are showed on the screen After viewing them press button to return to the function menu Figure 6 32 System info 6 8 8 User info Choose User info from the function menu and...

Page 23: ...vice D and DL should be operated separately Before calibration you should choose impact device from parameters menu first and then perform calibration for this impact device 6 8 10 Brightness Adjustme...

Page 24: ...e measurement at very narrow surface such as slot bottom gear tooth that probe D cannot match Please refer to the following steps to change impact body Unscrew the support ring from the tester and let...

Page 25: ...oper way of holding is important for obtaining better readings Attention the tester must be placed against object surface firmly and perpendicularly A slight gap between support ring of tester and sur...

Page 26: ...some time Please make sure to obtain additional or replacing battery from SALUTRON Otherwise it may cause the instrument to get un accuracy value In order to avoid damage of battery due to over discha...

Page 27: ...mode 9 3 System reset The instrument doesn t response possibly due to instable power voltage or others the instrument can be reset when it does not response Take the impact body out of the instrument...

Page 28: ...ndrical HZ 11 13 20 18 5mm R 11mm 13mm R 11mm not possible R 30mm D6a HZ 12 5 17 20 20 5mm R 12 5mm 17mm HZ 16 5 30 20 20 5mm R 16 5mm 30mm spherical K 10 15 20 7 7mm R 10mm 13mm R 10mm not possible R...

Page 29: ...wer indicator green light keep bright when the battery power 50 30 three color power indicator the yellow light keep bright when the battery is less than 30 three color power indicator the red light k...

Page 30: ...s the Drive Letter of the application CD x cp2102 Drivers CP210x USB Composite Device x cp2102 Drivers CP210x USB to UART Bridge Controller Install these two drivers 11 2 Installation of Software To r...

Page 31: ...nstalled during installation install the file NET35_SP1_cn exe that is located in X dotnet_35 folder in the CD You can also download it from the Microsoft website 11 3 Operation of PC Software Double...

Page 32: ...which is in the down left corner of the software window After checking an orange check displays that means the connection is created successfully Before Checking Device After Checking Device connecte...

Page 33: ...saved 11 3 4 Test data Click Test data tab in the working area or click button from the tool bar to load the Test data working area After connection is established you can return to the testing mode...

Page 34: ...isplay choose the file and click Open the saved data will be displayed in the current data area File Print to print current data Select Print from the File menu or click button the data in current win...

Page 35: ...click Read button to read the current parameters from the tester select new parameters in Preinstall area and click Modify button to change the current parameters Note Operations in Parameter tab must...

Page 36: ...l value of standard block in the standard value box and press Change standard value The default value is 500 The modified data is saved in the application 2 Calibration To take measurement on the stan...

Page 37: ...ew form Click button to open saved stored data Click button to read stored data Click button to save current data into Microsoft Excel document Click button to print current data to the default printe...

Page 38: ...36 11 4 Quit the program After finish all the job you can click from the tool bar to quit the program...

Page 39: ......

Page 40: ...tf S ri a e l d u C T r r e o m n er M A e ll s e s e t 3 e 0 c h 7 n ik D 5 G 0 m 22 b 6 H Dr Got Frechen Tel 49 0 2234 9999960 Fax 49 0 2234 9999962 Email info salutron de www salutron de...

Reviews: