background image

Change the Setpoint temperature

Frost Protection

Sleep Mode

RESET

PAIRING
/TEST

RESET

PAIRING
/TEST

ON

OFF

MANUAL AUTO

ON

OFF

MANUAL AUTO

ON

OFF

MANUAL AUTO

The thermostat displays 

measured room temperature.

Note:

 If you are using the DT300RF pack , the pairing between the thermostat and the receiveris already done. 

During the pairing process, please make sure the thermostat and the receiver are at least 1 meter from each other.

If you want to re-pair the devices with each other, follow the steps below:

To exit Installer Mode, wait 10 seconds, the thermostat will automatically return to the main screen.

Important note:

 The communication radius of the thermostat with the receiver is of maximum 100m, in 

open space. In built space, with various obstacles (eg walls, floors, metal structures, furniture elements), the 
communication radius will be significantly reduced. RF communication can be disrupted by local factors, such as 
GSM antennas, radio frequency devices or toys, or other equipment that produces electromagnetic interference.
Receivers for the boiler must be powered from a stable voltage source, without frequent interruptions or voltage 
fluctuations (outside the standard tolerance). The manufacturer is not responsible for identifying or combating 
the effects of local disturbances.

After 2 seconds, the new temperature 

setpoint will be overwritten.

The thermostat will display the measured temperature 

again. The heating mode icon will appear if the temperature 

setpoint is higher than the measured temperature.

Move the left switch to the OFF

position with a quick motion and

back to the ON position

Press and hold PAIRING / TEST button

behind the back cover cover for 3 seconds.

Press and hold PAIRING / TEST button

behind the back cover cover for 3 seconds.

When the thermostat enters sync mode, 

the screen will display S Y + a digit.

The pairing process can take up to 9 minutes. 

Once devices are successfully paired, 

the LED indicator will turn permanently green.

Press the RESET button under the 

back cover (you can use a paper clip), 

the thermostat will reset and restart 

automatically.

To insert and replace the batteries, follow the steps below:

1. Unlock the battery compartment.
2. Push the battery holder at the bottom of the thermostat
3. After adding or replacing the batteries, re-insert the battery  
     holder.

The green LED will start blinking,

which will confirm that the receiver

has entered the pairing mode

Press three buttons at the same time

for 3 seconds

Make sure that the receiver is

disconnected from the 

power supply

 

and the switches on it are in the 

AUTO and ON positions. 

Then connect the receiver to the 

power supply and wait for

the green LED to glow continuously.

When the snowflake icon is displayed 

then it means that the frost protection 

mode is active.

To exit sleep mode,

press twice any button.

To enter sleep mode, press and hold

          and           for 3 seconds.

Press          or         ,

to set the temperature.

Press             button to turn 

ON/OFF frost protection.

The Frostpoint temperature can be reviewed by pressing the            button once, but can only be changed 
in Installer Mode.

When Sleep Mode is active all the thermostat functions will be paused.

3 sec

3 sec

3 sec

3 sec

Pairing the DT300RF Thermostat with the DTRX3 Receiver

Installer Mode

Battery replacement

Reset of the DT300/DT300RF thermostat

1

4

6

7

5

2

3

3 sec

3 sec

3 sec

Press          to edit the parameter. 

To change the parameter value 

use            and               buttons.

dxx Function

Parameter value Default value

d01

Temperature display increments

0.1 °C or 0.5 °C

0.5 °C

d02

Temperature offset

+/- 3.0°C

0.0 °C

d03

Frost protection setpoint temperature

5.0 °C - 17.0 °C

5.0 °C

d04

TPI or SPAN algorithm selection 
TPI = self-adaptive algorithm
SPAN = hysteresis (fixed temperature deviation)

TPI or SPAN 

TPI

d05

TPI or SPAN adjustment (if you selected SPAN 
in parameter d04, then parameter d05 will 
display the SPAN settings, the same applies to 
the TPI algorithm)

6CP or 9CP  /
0.25 °C or  0.5 °C

6CP / 0.5 °C

Summary of Contents for DT300

Page 1: ...mail sales salus tech com SALUS Controls is a member of the Computime Group Maintaining a policy of continuous product development SALUS Controls plc reserve the right to change specification design and materials of products listed in this brochure without prior notice www salus controls com Issue Date May 2022 V03 ...

Page 2: ... 30 EU LVD 2014 35 EU RED 2014 53 EU and RoHS 2011 65 EU The full text of the EU Declaration of Conformity is available at the following internet address www saluslegal com Introduction Product compliance Technical specification Safety Information Use in accordance to national and EU regulations Use the device as intended keeping it in dry condition Product for indoor use only Installation must be...

Page 3: ...eatingModeON 2 FrostProtectionModeON 3 RFsignalindicator onlyforDT300RF 4 Lowbatterystatus 5 Temperatureunit 6 Room setpointtemperature 2 5 6 1 3 3 1 2 4 4 1 TurnontheLCDbacklight 2 TurnOn OfftheFrostMode 3 Increasebutton 4 Decreasebutton 5 When in manual mode ON will turn the boiler on Wheninmanualmode OFFwillturntheboileroff 6 Receiver operates in automatic mode according to the thermostat Recei...

Page 4: ... COM DT300RF 3V 2 X AA 3V 2 X AA MAX 16 5 A DT300RF BOILER CONNECTION AC 230V AC 230V DT300 3V NC NO COM 2 X AA 3V NC NO COM 2 X AA MAX 5 3 A BOILER CONNECTION DT300 Legend Symbols explanation DT300ThermostatWiring Diagram DT300RFThermostatWiring Diagram OR OR Boiler Boiler connection Boiler s contacts for ON OFF thermostat according to the boiler s instructions L N Power supply 230V NO COM NC Vol...

Page 5: ...herthanthemeasuredtemperature When the snowflake icon is displayed then it means that the frost protection mode is active To exit sleep mode press twice any button To enter sleep mode press and hold and for 3 seconds Press or to set the temperature Press button to turn ON OFF frost protection The Frostpoint temperature can be reviewed by pressing the button once but can only be changed in Installe...

Page 6: ...esource withoutfrequentinterruptionsorvoltage fluctuations outside the standard tolerance The manufacturer is not responsible for identifying or combating theeffectsoflocaldisturbances Move the left switch to the OFF position with a quick motion and back to the ON position Press and hold PAIRING TEST button behind the back cover cover for 3 seconds Press and hold PAIRING TEST button behind the bac...

Page 7: ...onds Installer Mode Battery replacement Reset of the DT300 DT300RF thermostat 3 sec 3 sec 3 sec Press to edit the parameter To change the parameter value use and buttons dxx Function Parameter value Default value d01 Temperature display increments 0 1 C or 0 5 C 0 5 C d02 Temperature offset 3 0 C 0 0 C d03 Frost protection setpoint temperature 5 0 C 17 0 C 5 0 C d04 TPI or SPAN algorithm selection...

Reviews: