manualshive.com logo in svg
background image

Installation and  
operating instructions 

Room thermostat 

RAMSES

RAMSES 811 top2 

RAMSES 831 top2

811 9 132   

831 9 132

   

RAMSES 812 top2 

RAMSES 832 top2

812 0 132   

832 0 132

309 358 02

GB

D

GB

F

NL

E

I

RAMSES 832 top2

Содержание RAMSES 811 top2

Страница 1: ...allation and operating instructions Room thermostat RAMSES RAMSES 811 top2 RAMSES 831 top2 811 9 132 831 9 132 RAMSES 812 top2 RAMSES 832 top2 812 0 132 832 0 132 309 358 02 GB D GB F NL E I RAMSES 832 top2 ...

Страница 2: ...rview 14 Change target temperature 15 Set date time and summer winter time 15 Set holiday program etc 16 Programming 18 Reset switching time 19 Change or clear switching time 20 View switching time 21 Delete program 21 Set language 22 Set display 22 Set LCD backlight 23 Set contrast 23 Set keypad lock 24 Set factory settings 24 Operating level for specialist personnel 25 Set wall compensation 25 S...

Страница 3: ...use The room thermostat controls the room temperature in houses offices etc It is used in dry rooms with normal levels of domestic cleanliness Disposal Dispose of device and batteries in an environmentally sound manner Danger of death through electric shock or fire Installation should only be carried out by a qualified electrician WARNING GB ...

Страница 4: ...n Days of the week from 1 7 Function keys MODE PARTY ECO INFO Display programmed switching times Scroll through menu or change values Time display Operating instructions YES Confirmation Press OK NO Amend change press bbbb 1 Read text line Flashing text symbol represents query bbbb 2 Make a decision ...

Страница 5: ... power source Cover or shield any adjacent live components Ensure device cannot be switched on Check power supply is disconnected Earth and bypass WARNING GB L L N N T1 T2 L N 3 2 8 8 1 7 7 6 5 4 3 2 1 L L N N T1 T2 L N 3 2 8 8 1 7 7 6 5 4 3 2 1 controlling circulation pump or actuator controlling burners or gas water heaters ...

Страница 6: ...6 Installation Fix plate to wall and attach device Ensure installation height of approx 1 5 m Dismantling Insert screwdriver from below push detent hooks up and open device ...

Страница 7: ...display flashes the controller is no longer active the relay remains permanently switched on The batteries must be replaced immediately Insert batteries Only use alkaline 1 5 V AA batteries Ensure correct polarity when fitting batteries Reset Press a pointed object into the opening on the left hand side of the device 7 GB ...

Страница 8: ...ions see fig Date time and summer winter rule can be set via MODE menu under TIME DATE Date and time have to be set with the RAMSES 811 top2 and RAMSES 812 top2 models RAMSES 831 top2 and RAMSES 832 top2 are factory set RAMSES 811 top2 and RAMSES 831 top2 are battery devices RAMSES 812 top2 and RAMSES 832 top2 are mains devices GERMAN YEAR MONTH DAY HOUR MINUTE ROOM TEMP 21 6 C 8 ...

Страница 9: ...y View settings The INFO key allows you to access current room temperature temperature program setpoint temperature date time or battery status Press INFO key repeatedly User information ROOM TEMP 21 6 C P1 ACTIVE TARGET TEMP 22 4 C 02 02 2009 15 31 BATTERY ROOM TEMP 21 6 C or P2 ACTIVE P3 ACTIVE PERM COMFORT PERM REDUCED FROST PROTECTION or PARTY TARGET TEMP ECO TARGET TEMP GB ...

Страница 10: ...ws ECO OFF Change ECO TARGET TEMP The rotary control adjusts the ECO TARGET TEMP up or down PARTY key Set PARTY function Press PARTY key The display shows PARTY TARGET TEMP 23 0 C Provided the whole screen is shown the PARTY key flashes to display the set party mode The INFO key plus the PARTY key appear once the contents of the screen are faded out Delete PARTY function Press PARTY key The displa...

Страница 11: ...1 P2 P3 The programs are adjusted using the MODE key in the SETTINGS menu see page 13ff Use rotary control to make changes In standard operation mode you can temporar ily change current setpoint temperature via the rotary control It is not stored in the program and is replaced by the set value at the next programmed switching time Turn rotary control up or down to change temperature setting in 0 2...

Страница 12: ...rograms The broken bar in the top left of the display shows the number of menu points in the relevant menu The flashing cursor indicates the point in the menu that you are currently in P1 COMFORT 1 6 20 1 2 3 4 5 6 7 ESC NEW NEXT EDIT ...

Страница 13: ...nu point brings up the programming and setting mode Select preset program Press MODE key Use or to scroll through menu points select desired program and confirm by pressing OK P1 ACTIVE ACTIVATE P2 P2 ACTIVE ACTIVATE P3 PERM COMFORT PERM REDUCED FROST PROTECTION SETTINGS MODE 13 GB ...

Страница 14: ...ED TEMP FROST PROTECTION PROGRAMM ING HOLIDAY OPTIONS SERVICE PROG P1 PROG P2 PROG P3 CLEAR PROG START HOLIDAY YEAR MONTH DAY LANGUAGE DISPLAY HOUR END HOLIDAY FROST PROTECTION LCD BACKLIGHT CONTRAST KEY LOCK FACTORY SET WALL COMP OPTIMISE PUMP PROTECTION EXT INPUT CONTROLLER SERVICE INFO 14 only RAMSES 811 top2 RAMSES 812 top2 ...

Страница 15: ...quired Comfort 1 3 10 2 C 30 C Reduced temperature min 10 C max 0 2 K under Comfort 1 Frost protection from 4 C 10 C Set date time and summer winter time Confirm TIME DATE by pressing OK The display shows HOUR Change hours minutes etc in succession using the or keys or the rotary control Confirm by pressing OK SETTINGS TARGET TEMP COMFORT 3 COMFORT 2 COMFORT 1 REDUCED TEMP FROST PROTECTION TIME DA...

Страница 16: ...r keys or rotary control to change value Confirm each setting by pressing OK Finally enter END HOLIDAY in same way as START HOLIDAY entry Set desired temperature for the holiday period using the or keys and confirm with OK A maximum of one holiday period can be entered HOLIDAY START HOLIDAY YEAR MONTH DAY HOUR END HOLIDAY SETTINGS ...

Страница 17: ...the holiday mode has been switched off Confirm HOLIDAY on display with OFF The display shows HOLIDAY OFF 17 HOLIDAY 21 6 C HOLIDAY OFF OFF Set temperature preselection View clear holiday program only possible with a programmed holiday period FROST PROTECTION REDUCED TEMP COMFORT 1 COMFORT 2 HOLIDAY CHECK CLEAR HOLIDAY YEAR DAY MONTH GB ...

Страница 18: ...gram P2 preset Mon Fri Comfort 1 6 00 8 00 16 00 22 00 otherwise reduction temperature Sat Sun Comfort 1 7 00 23 00 Program P3 preset Mon Fri comfort 1 12 00 20 00 otherwise reduction temperature Sat Sun comfort 1 7 00 22 00 Briefly interrupt holiday program and restart The program can be interrupted during the holiday period and restarted with the available data Confirm HOLIDAY on screen by press...

Страница 19: ...un individual days or daily Confirm by pressing OK Select desired temperature using the or keys or the rotary control comfort 1 3 reduced temp frost protection Confirm by pressing OK Enter switching time in hours and minutes using the or keys or the rotary control Confirm by pressing OK PROG P1 PROG P1 P1 Mon Fri 1 2 3 4 5 P1 Sat Sun 6 7 DAILY 1 2 3 4 5 6 7 P1 MONDAY 1 P1 COMFORT 1 0 00 1 2 3 4 5 ...

Страница 20: ...ontrol e g Mon Fri Sat Sun individual days or daily Confirm by pressing OK Select temperature using the or keys or the rotary control comfort 1 3 reduced temp frost protection and confirm by pressing OK Enter switching time in hours and minutes using the or keys or rotary control and confirm by pressing OK PROG P1 P1 Mon Fri 1 2 3 4 5 P1 Sat Sun 6 7 CHANGE 6 00 6 7 CLEAR 6 00 6 7 DAILY 1 2 3 4 5 6...

Страница 21: ...ammed switching times can be viewed in succession Delete program Confirm PROGRAMMING by pressing OK Select CLEAR PROG using the or keys Confirm by pressing OK The display shows CONFIRM Confirm by pressing OK PROGRAMM ING PROG P1 PROG P2 PROG P3 CLEAR PROG CONFIRM SETTINGS 21 PROG P1 END NEXT P1 COMFORT 1 6 20 1 2 3 4 5 6 7 P1 COMFORT 1 2 20 1 2 3 4 5 6 7 GB ...

Страница 22: ...ng OK Use or keys or rotary control to select values 1 3 Confirm by pressing OK OPTIONS LANGUAGE DISPLAY LCD BACKLIGHT CONTRAST KEY LOCK FACTORY SET SETTINGS 22 1 Standard display after 5 seconds all display content except for temperature and time are faded out 2 Standard display Time and temperature are swapped round 3 complete display 12 00 21 3 C 12 00 ROOM TEMPERATURE 21 3 C 18 3 12 00 ...

Страница 23: ...CKLIGHT by pressing OK The display shows for example 3 Use or keys or the rotary control to select 0 3 Confirm by pressing OK Set contrast Screen contrast can be set at different levels Confirm CONTRAST by pressing OK The display shows forexample 8 Use or keys or the rotary control to select 0 15 Confirm by pressing OK 23 GB ...

Страница 24: ...ay shows WITH or NO KEY LOCK Confirm selection by pressing OK Briefly interrupt keypad lock The keypad lock can be interrupted to allow programming etc The keypad lock is reacti vated once changes are completed and the standard operating mode is returned to Press INFO key for more than 3 seconds Set factory settings The factory settings return all controller set tings to delivery status Confirm FA...

Страница 25: ...nfirm SERVICE by pressing OK The display shows WALL COMP Confirm WALL COMP by pressing OK Use or keys or rotary control to change the temperature setting and confirm by pressing OK SETTINGS SERVICE WALL COMP OPTIMISE PUMP PROTECTION EXT INPUT CONTROL SERVICE INFO 25 0 3 WALL COMP 21 3 C Offset value difference between measures and displayed temperature Temperature value Operating level for special...

Страница 26: ... room thermostat stops heating request for bathroom at 06 00 Depending on the size of the room and heating system used the bathroom reach es the desired 23 C at 06 30 for example With a set optimisation of 5 min K the thermostat requests the heating requirement earlier as follows Setpoint temperature at 06 00 23 C Actual temperature 17 C i e Delta T 6 K 6 K 5 min K 30 min The controller starts the...

Страница 27: ...nd confirm by pressing OK PUMP PROTECTION ON TIME 11 30 DURATION 0 40 PUMP PROTECTION Set external input The external input on the RAMSES 832 top2 can be configured for various external sensors CAUTION Input is active therefore do not use external voltage Confirm EXT INPUT by pressing OK You can choose from UNUSED INPUT FLOOR SENSOR ROOM SENSOR WINDOW SWITCH PHONE SWITCH PRESENCE DETECTOR Confirm ...

Страница 28: ...isplay floor sensor 907 0 321 Room sensor no options internal temperature sensor is switched off external temperature sensor IP 65 907 0 459 Presence detector Temperature selection this temperature is controlled when the HVAC output on the presence detector is switched on If no presence is detected the set program is used Window switch no options provided the window switch is switched on the therm...

Страница 29: ... phone switch turns off automatically TELEPHONE SWITCH is shown on screen if the phone switch is switched on The switched contact must be switched off manually to allow the control to be used again A safety shutdown switches the contact off again automatically at the preset time The telephone remote switch used should have a pulse output 29 GB ...

Страница 30: ...high control accuracy Controller characteristics of a hysteresis on off controller With over or undersized heating systems hysteresis controllers are noted for their mini mal switching frequency and low temperature variations Confirm CONTROL by pressing OK You can choose between PD CONTROL or HYST CONTROL Use or keys or rotary control to implement settings and confirm by pressing OK 30 ...

Страница 31: ...essing OK The display shows MONTHS BEFORE NEXT SERVICE Use the or keys or the rotary control to enter the value and confirm by pressing OK SERVICE MONTHS BEFORE NEXT SERVICE 12 CONTROL PERIOD 10 HYST CONTROL HYSTERESIS 0 2 C HYST CONTROL PD CONTROL PD CONTROL CONTROL OFFSET 0 1 C AMPLITUDE 1 2 C 31 GB ...

Страница 32: ...on Type 1 B in accordance with EN 60730 1 Contact Two way switch floating max 6 1 A 250 V min 1 mA 5 V DC Contact material AgSnO2 Temperature range 6 C to 30 C in increments of 0 2 C Permissible ambient temperature 0 C 55 C Control period 5 30 min PD controller Control capture range 0 2 K to 5 K PD controller Switching hysteresis 0 2 K to 1 0 K hysteresis controller Memory locations 42 Protection ...

Отзывы: