51
The splicer suddenly shut down
The splicer turned off automatically when the machine
is set for automatic machine shutdown (default 30
minutes) without any operations.
Fiber identification errors under
AUTO mode
AUTO mode only for standard SM, MM, NZ optical
fibers. When splice special fibers, AUTO mode may
not recognize correctly.
The estimated loss is different from
the real loss
1) The estimated loss is evaluated just for reference.
2) The optical components needed to be cleaned.
Heat shrinkable tube doesn’t shrink
completely
Extend the heating time.
How to cancel heating
If user want to terminate the heating, press HEAT
button, then the LED light will turn off.
The heat shrink tubing is stuck in
the heating tank after heating
Remove the heat shrink tubing with a thin cotton swab
or soft bar.
After discharge calibration, the
discharge intensity did not change
The discharge calibration changes the internal
condition parameters, not the discharging strength.