19
2) Confirm splicing and heating mode, when splice different types of fibers, Auto
Mode is suggested, splicing speed will be slower.
3) Clean the fiber or heating shrinkable tube.Penetrate the fiber into heat
shrinkable tube.
4) Strip the fiber and clean it with 99% or better purity alcohol. Make sure the
coating trash or dirt is wiped out.