The red LED should remain on for those 40 seconds. After these 40 seconds, the LED
will blink continuously showing that it is no longer in set-up mode and that it is in stand-
by and ready to work.
If the LED does not follow the process explained above, the installation has not been
completed correctly.
2.3 Desynchronization of detectors
To desynchronize a Detector from an Energy Saver, present the Detector Deleting Card
to the Energy Saver. The Energy Saver then deletes the list of synchronized Detectors.
Desynchronization is necessary when:
• One of the room’s Detectors will be removed and deleted.
• A Detector has been damaged and needs to be replaced..
Please note that after a desynchronization, it is always required to synchronize the
Energy Saver to any Detectors operating in the same room.
Note that it is NOT necessary to desynchronize when a motion detector’s batteries are
changed or when an additional motion detector is added to the room.
3. DETECTOR CONFIGURATION
IMPORTANT! The configuration process is NOT a normal operational activity
and should be done only under exceptional circumstances.
The Door/Window Detector can function as either a Door Detector or a Window
Detector depending on how the Detector is configured.
By DEFAULT, the Detector is configured as a Door Detector.
3.1 Door Detector configuration
This is the default configuration of the Detector because it is the most common
application. To synchronize with the Energy Saver, please follow the steps above.
3.2 Window Detector configuration
In order to configure it as window detector:
If the detector has the following built-in dip-switch please continue to b) section: