background image

SCALE CALIBRATION INSTRUCTIONS                                              

Periodically your scale may require calibration to ensure proper weighing.  You will

need  a  10-pound  weight  to  calibrate  the  scale.  If  calibration  is  performed  with  a

weight other than 10 pounds, it will cause  your scale to weigh inaccurately.  Scale

calibration is accomplished, when needed, by the following instructions:

Function

Scale Response

1. Remove all weight from the scale

2. Press and hold the “ON/TARE” key and

press the “lb-oz/grams” key once . . . . . . . . . . . . . .“ . . .SLP0/SLP1”

3. Press the “ON/TARE” once to accept the

sleep mode setting and enter into calibration mode. . . .”4000 – 10000”

4. Press the “ON/TARE” key once

to zero the scale. . . . .  . . . . . . . . . . . . . . . . . . . . . . . . . .“0”

5. Place 10 lbs on the scale . . . . . . . . . . . . . . . . . . . . . ..“6400 - 10,000”

6. Press “ON/TARE” key once

to accept the calibration weight . . . . . . . . . . . . . . . . . . . .“CAL” then 

* “Err”

7. Remove the weight from the scale, press the “ON/TARE” key to continue the

normal weighing mode.

* Note:  

 The “Err” displayed after completing calibration does not indicate a

 calibration error.  Since, the scale only weighs up-to 9 lbs. 15.5 oz., the ten

 pounds on the scale causes the displayed message “Err

5

INTERFACING TO A PC                                                                    

The Model 7010SB interfaces to several Mailing and Internet Postage Software

Programs.  A driver is not available from Salter Brecknell, please contact the

software manufacturer for their 7010 or 7010SB scale driver.

Salter Brecknell does offer a Active X control for you to develop your own interface

driver. ActiveX allows programmers to assemble reusable software components into

application programs.

ActiveX components must be used is a (32-bit) ActiveX compliant development

environment such as Microsoft Visual Basic 5,0, Visual C ++, Office 97, Visual

FoxPro, Borland Delphi and others.

To download the ActiveX Component and other use tools to help you write and

interface to the 7010SB.  Visit our web site at www.salterbrecknell.com

Salter Brecknell can only offer limited support to software developers.

INTERFACE SPECIFICATIONS          

Communications:  RS-232, No-Handshake, continuous transmit only.

    Fixed 2400 Baud, 8 data bits, No parity, 2 stop bits.

             Fixes ASCII character continuous transmission.

Weight and Status Response:  

<STX> X  

X  X 

# # # # <CR>

STATUS BIT DEFINITIONS

S6  S5  S4   Definitions:

0     0     0    n/a

0     0     1    n/a

0     1     1    weight is in pounds: ounces

1     0     0    weight is in grams

To download more detailed interface specifications, please visit our web site at

www.salterbrecknell.com

, 7010SB serial communications protocol.

6

Reviews: