background image

 

 

USER’S MANUAL 

 

MA07-02/B 

15/09/2011 

 
 
 

 

 

www.davicia.com 

Summary of Contents for DAVIVENDY

Page 1: ...USER S MANUAL MA07 02 B 15 09 2011 www davicia com ...

Page 2: ...rogramming advertising 4 2 4 Programming the ticket 4 2 5 Programming the logo 4 2 6 Smart card programming 9 9 9 9 10 10 11 12 12 5 5 5 5 MAINTENANCE AND CLEANING MAINTENANCE AND CLEANING MAINTENANCE AND CLEANING MAINTENANCE AND CLEANING 5 1 Cleaning the blood pressure cuff 5 2 Paper roll change 5 3 Equipment disposal 14 14 14 15 6 6 6 6 TROUBLESHOOTING TROUBLESHOOTING TROUBLESHOOTING TROUBLESHOO...

Page 3: ... 2 1 DESCRIPTION 1 Height meter sensor 2 Height meter arm and leds 3 LCD Display 4 Chip card reader 5 Coin slot 6 Ticket tray 7 Body fat sensors 8 Access door for paper roll change 9 Power switch fuses cable 1 2 3 4 5 6 7 8 9 ...

Page 4: ...here it is perfectly supported This last point is of vital importance to proper operation Make sure that within a radius of 70 cm around the equipment there is no interference that might affect the measurement of height 2 2 STARTUP 2 2 STARTUP 2 2 STARTUP 2 2 STARTUP o Connect the equipment to the power supply o Check that no objects are placed on the platform of the equipment o Actuate the switch...

Page 5: ...sing START it begins the process for Weight and Height o If you introduce the remaining amount up to the second price it is automatically activated When the equipment operates with a single price by reaching the programmed amount the service is activated automatically without pressing any key 3 1 1 Using 3 1 1 Using 3 1 1 Using 3 1 1 Using smart smart smart smart cards cards cards cards The main u...

Page 6: ...e new credit is automatically recorded on the smart card and we can remove it from the equipment 3 2 WEIGHT AND HEIGHT 3 2 WEIGHT AND HEIGHT 3 2 WEIGHT AND HEIGHT 3 2 WEIGHT AND HEIGHT Before starting the measurement appear on screen instructions for the correct posture we must take step up to the platform stand straight After a few seconds the measurement is carried out automatically IMPORTANT By...

Page 7: ...start the measurement press the START button You hear a beep and the cuff inflating process begins The cuff is inflated to get to 250 mmHg then the pressure starts to drop automatically at a speed of 3 mmHg sec Simultaneously with the detection of each pulse the screen draws a heart and you hear a beep that accompanies it DAVI CIA 250 mmHg Upon completion of the measurement the values obtained app...

Page 8: ... following cases o During an acute contagious disease o In people with medical implants eg a pacemaker o In people with abnormal blood pressure or any heart disease Input data To calculate your body fat you need to enter some input which must be within the following ranges o Weight 45 0 kg to 225 0 kg o Height 140 cm to 205 cm o Age 10 to 80 years Otherwise the computer ignores the process of calc...

Page 9: ...cates when the measurement is complete and you can take your hands off the sensors The equipment takes into account the following user data to output the result values o Age o Sex o Complexion optional depending on configuration If not using a smart card you must enter the data using the computer keypad Follow the instructions on each screen to correctly enter each of the requested data If you use...

Page 10: ...ck setting PRICES Price programming ADVERTISING Programming advertising TICKET Programming the ticket LOGOS Programming the logos CARD Smart card programming Keypad operation Programming is done using the main keypad whose keys have multiple functions numbers and letters Pressing more than once a number key makes appear the various programmed characters press the key once displays the first charac...

Page 11: ... Price for Body Fat measurement PRICE 3 Price for Blood Pressure measurement FREE All measurements free If for example we selected 1 Weight Height the display shows the following message PROGRAM PRICES PRICE 1 Using the keypad enter the amount desired for Price1 We can set different prices for the different services that are configured Depending on the value of the service we can have one or more ...

Page 12: ...ressed key NOTE To enter a blank line is necessary to program at least one character of the line as space To delete a line simply enter the line and press START without programming any character IMPORTANT It is very important that LINE 1 is always programmed as it always appears on the screen header 4 2 4 Programming of the ticket 4 2 4 Programming of the ticket 4 2 4 Programming of the ticket 4 2...

Page 13: ...pear in the selected line with the alphanumeric keypad When finished press START to confirm the data The screen displays the information of Line number column and character set for the pressed key NOTE To enter a blank line is necessary to program at least one character of the line as space To delete a line simply enter the line and press START without programming any character 4 2 5 P 4 2 5 P 4 2...

Page 14: ...ramming menu means that the card has been successfully created Add credit Using the programming menu is possible to add credit to the smart card Press 2 to start SMART CARD PROGRAMMING CREDIT 00 00 VALUE Enter the value to charge in the card using the keypad Press START to confirm The entered value is added to the card credit Setup a discount You can apply a discount to all operations performed by...

Page 15: ...sonnel authorized personnel authorized personnel from the Davi Cia Technical Support Service from the Davi Cia Technical Support Service from the Davi Cia Technical Support Service from the Davi Cia Technical Support Service can perform can perform can perform can perform Clean the unit using only a soft cloth Do not use gasoline or any similar solvent 5 1 CLEANING THE BLOOD PRESSURE CUFF 5 1 CLEA...

Page 16: ...L EQUIPMENT DISPOSAL All electrical and electronic products should be disposed of separately from the municipal waste stream via designated collection facilities appointed by the government or the local authorities This crossed out wheeled bin symbol on the product means the product is covered by the European Directive 2002 96 EC The correct disposal and separate collection of the equipment will h...

Page 17: ...inflating process time has exceeded Failure in air pressure circuit Failure in pressure measuring PNEUMATIC ERROR CODE 13 Problem caused by abnormal function during the detection process Failure in air pressure circuit Failure in pressure measuring PNEUMATIC ERROR CODE 14 Problem caused by abnormal memory function Failure en la E2PROM de la PressV3 Failure in I2C circuit PNEUMATIC ERROR CODE 15 Th...

Page 18: ...d failure Paper finished Paper feed failure Paper detector failure CARD ERROR CODE 50 Smart card failure in R W Bus I2C failure Card reader failure Card failure UNKNOW CARD CODE 51 Card not recognized Card code unknown UNKNOWN ERROR CODE 99 Unknown error ...

Page 19: ...urement B I A Measurement accuracy Weight Height Static pressure Body fat Non metrological 100 g n 3000 Metrological Class accuracy C n 3000 1 cm 3 mmHg 2 Power supply 230V 50 60 Hz 115V 50 60 Hz Consumption In operation max 50 VA In operation Body fat index Temperature Humidity Other parameters Temperature Humidity 15 ºC to 40 ºC 30 to 75 0 ºC to 40 ºC 30 to 75 Printer Thermal printhead 8 dots mm...

Page 20: ...e 2004 108 CE Sphygmomanometer Directive 93 42 CE Class IIa Applicable Standards SEGURIDAD ELÉCTRICA Electrical Security UNE EN 60601 1 1990 A1 1993 A11 1993 A12 1993 A2 1995 A13 1996 EN 60601 1 2 2001 EMISIÓN ELECTROMAGNÉTICA EM Emission EN 55011 1998 A1 1999 A2 2002 Radiada Radiated EN 55011 1998 A1 1999 A2 2002 Conducida Conducted INMUNIDAD ELECTROMAGNÉTICA EM Immunity EN 61000 4 2 1995 A1 1998...

Page 21: ...fied free of charge upon presentation of the purchase receipt for the appliance No other rights can be taken into consideration Return shipment is at the customer s expense if the appliance is anywhere other than at the customer s headquarters In the event of damage during shipment guarantee rights will be granted only if the appliance is shipped in the original packaging You are therefore recomme...

Page 22: ...QUISITES OF THE DIRECTIVES Pesapersonas Tallímetro y Analizador de Grasa Corporal Weighing scales Height rod Body fat analyzer EC Directive 2004 108 CE Directiva de Compatibilidad Electromagnética Electromagnetic Compatibility Directive EC Directive 90 384 CEE Directiva de Instrumentos de Pesaje No Automático Non Automatic Weighing Instruments Directive Esfigmomanómetro Sphygmomanometer Conforme a...

Page 23: ...uments are available on the web www davicia com www davicia com www davicia com www davicia com C Murcia 35 Nave G Pol industrial Can Calderón E 08830 Sant Boi de Llobregat Barcelona Spain Tel 34 93 654 32 32 Fax 34 93 654 16 62 info davicia com www davicia com ...