13
Pompes Salmson SAS
English
The motor head can then be simply unscrewed.
5 Installation
5.1 Installation site
Provide a weatherproof, frost-free, dust-free and well-ventilated room for the
installation. Choose an installation site that is easily accessible.
CAUTION!
Dirt can cause the pump to fail. Flush the pipe
system before installation.
NOTE: In the case of the Zen Ô home V version.
the stop valve and non-return valve are pre-
installed. In the case of the Zen Ô home
version, these valves have to be installed
additionally.
1
Prepare the installation site so that the pump
can be installed without being exposed to
mechanical stresses.
2
Choose the right installation position - only as
shown in (Fig. A). The arrow on the back of the
housing indicates the direction of flow.
DANGER!
Before establishing the connection, make sure that the
connecting cable is dead.
3
Release the union nut - unscrew it completely if
necessary.
CAUTION!
Do not damage the housing seal. Replace damaged seals.
4
Turn the motor head so that the Salmson-Connector
points downwards.
CAUTION!
If the position is wrong, water can penetrate and destroy
the pump.
5
Tighten the union nut again.
6
Turn slot (1) with a screwdriver so that it is parallel to the
direction of flow (only in the case of the Zen Ô home V
version).
1