5
Pre-installation
Installation
PumpWise guidelines
General specification
Trouble shooting
PumpWise and warranty
The plumbing installation must comply
with “The Water Supply (Water Fittings)
Regulations 1999” and “BS EN 806-
4:2010” buildings regulations.
5 Electrical requirements
The pump must be connected to the
electrical supply using the mains cable
with the attached plug. This plug must be
connected to an accessible socket that has
been installed in compliance with BS 7671
(I.E.T. Wiring Regulations). The plug must be
accessible at all times.
The pump must not be installed in a
bathroom unless it is installed in an
enclosed space accessible only with the use
of a tool.
If the supply cord is damaged, it must be
replaced by the manufacturer, its service
agent or similarly qualified person in order
but they must NOT be twisted or bent more
than 35º (this invalidates the warranty).
See Figure 5 above.
Each single pump is supplied with two
couplers; one angled and one straight.
The angled coupler should be attached to
the pump inlet (on the side) and the straight
coupler should be attached to the pump
outlet (on the top).
Each twin pump is supplied with four
couplers; two angled and two straight.
For all pumps, the inlets are on the side of
the pump and the outlets are on the top of
the pump.
The AV couplers MUST only be tightened
to finger tight plus one quarter turn.
Mechanical tools must NOT be used to
tighten coupler nuts as this may cause
damage which will invalidate your warranty.
4 General plumbing
The installation must comply with the
relevant requirements or local by-laws.
The pump MUST be mounted upright (shaft
horizontal, not screwed down).
Jointing compounds, Boss White, hemp
or steel wool MUST NOT be used. Solder
fluxes must not come into contact with the
pump or AV couplers.
The maximum static head should be 10m
(equivalent to 100kPa/1.0 bar pressure)
with the exception of the RP50TU where
the maximum static head should be 5m
(equivalent to 50kPa/0.5bar pressure)
Pump
Fuse
RP55PS, RP80PS and RP120PS
3 amp
RP50PT
3 amp
RP75PT and RP100PT
5 amp
RP55SU, RP80SU, RP120SU and
RP50TU
3 amp
RP75TU and RP100TU
5 amp
We recommend that the pump is run
for at least 5 minutes every 4 weeks in
order to exercise all working parts.