Figure 1: Tank inlet and outlet position
Multiple cold water storage tanks MUST be
linked in 28mm pipe work with the bottoms
of the tanks at the same level.
To Pum p
To Cylinder
O utlet to
cyli
nder
Inlet
Bottom of cold
tank m ust be
cleare
d of debris
O utlet to pum p
Fig 1
OLD STYLE DO NOT USED
Fig 2
Figure 2: Linked cold water tanks
2.3 Hot water requirements
The stored hot water temperature must
not exceed 60ºC (see page 17, Stored hot
water temperature).
The hot water supply to the pump must be
via a Salamander approved method:
The best hot connection from the cylinder
is either
• A 3⁄4” NO STOP ESSEX FLANGE. See
Figure 3 or
• Alternatively a Salamander S flange or
other approved top entry flanges. See
page 15/16.
• Never fit to top entry flange if the pump
is fitted above the cylinder.
Pump at the base of cylinder
Outlets
OR ALTERNATIVELY
22mm No Stop Essex
flange with 76mm dip
pipe and birds beak cut
end to limit air being
drawn into the pump
Indirect coil
Pump inlet
Fig 3a
Pump inlet
A Salamander S flange or
one of the 22mm approved
top entry flanges listed
on page 15-16
MAX
60˚C
Figure 3: Hot water supply method
3. Anti-vibration couplers
(Hoses)
The anti-vibration (AV) couplers are
designed to limit the transfer of pump
vibration to the associated pipe work. All
Salamander AV couplers are
¾
” BSP x
22mm push fit with built-in isolating valves.
Note: the RP50PT and RP50PS are supplied
with 15mm couplers with isolating valves
35°
Isolating valve
shown in
‘ON’ position
Isolating valve
shown in
‘OFF’ position
35°
Do not bend hoses
more than 35°
Do not twist or
kink the hose
on the inlets and outlets.
Figure 4: Isolating valves
Figure 5: Couplers
Ideally the AV couplers should be straight,