Fault
Probable cause
Recommended solution
Pump will not start
Electrical
Check power supply
Check fuse
Check circuit breaker
Inlet/outlet connections
incorrect
Check that connections are plumbed the correct
way round and all valves are open
Float sticking in outlet
Flow switch malfunction
Ensure no debris is in outlet area
Contact our technical advisors on 0191 516 2002
Reduced/
intermittent flow
Incorrect or no anti-aeration
flange fitted
Check that installation complies with Salamander
instructions
Blocked inlet filters
Ensure that all filters and shower head are free
from debris
Couplers restricting flow
Ensure that all AV couplers are straight and not bent
or distorted
Air in system
Run system on full hot with pump switched off
(i.e. gravity only) for several minutes.
Check cold water storage is correct for installation
and pump is fitted to Salamander instructions.
Ensure cold water refill rate is adequate for
installation.
Check that vents are fitted as described in
instructions.
Wrong size pump for system
Ensure pump is sufficient to run the equipment
Hot temp set too high
Reduce cylinder stat setting to 65ºC max or fit HWS/
TMV
Pump starts with all
outlets closed
Leak in system
Check for leaks
Outlet open
Ensure all outlets are fully closed or capped – i.e. no
dead legs in pipework
Pump is noisy
Air in system
See previous page
Pump vibrating on surface
Ensure rubber feet are fitted to pump
AV couplers causing vibration Ensure that all AV couplers are straight and not bent
or distorted
Pump is leaking
Pump exposed to mains
water pressure
Check that installation complies with Salamander
instructions
Pump has suffered chemical
damage
Ensure that the pump has not come into contact
with chemical substance i.e. solder flux
Pump exposed to excessive
temperature
Is effective temp control fitted (cylinder stat or HWS/
TMV valve)?
Pump appears to have leaked
but not sure
Check leak is not from fitting in pipework above
pump
Pumps above hot
cylinder becomes
noisy/low pressure
during use
Aeration or water starvation
An essex flange may be required for the hot
connection to cylinder. Ensure pump is a minimum
of 600mm below the cold water tank.
x203623_salamander_p2_lh.indd 18
14/02/2019 13:04
Summary of Contents for EVE
Page 1: ...1 Pump Installation and Warranty Guide ISSUE A...
Page 7: ...7 Assembling EVE 12 8 8 12 11 11 10 10 9 9...
Page 11: ...11 1 5 4 8 9 7 3 6 11 10 2 Figure 1...
Page 12: ...12 4 1 2 5 3 Figure 2...
Page 21: ...21 Notes...
Page 22: ...22 Notes...
Page 23: ...23 Notes...