14
MODE 1:
EVE will maintain an outlet
pressure of
1.5bar
up to 40L/min
by dynamically changing speed.
MODE 2:
EVE will maintain an outlet
pressure of
2bar
up to 40L/min by
dynamically changing speed.
MODE 3:
EVE will produce an outlet
pressure of
3bar
by static speed
performance.
N.B. – In the dynamic modes, the pump
will increase motor speed, to maintain the
pressure for increased flows. So a tap turning
on elsewhere, won’t mean your shower loses
pressure. EVE will speed up to adjust for it.
All modes can be used in positive head and
negative head installation types.
MODE selection
The output pressure of the pump can be varied through three user-selectable modes:
To change the mode:
N.B. - The mode can only be changed whilst the EVE is ON and not running (no flow).
1.
TOUCH and HOLD the MODE selector
until the next mode LED comes on
-
STOP PRESSING MODE
2.
TOUCH again to move on to the next
mode.
-
STOP PRESSING MODE
Every time the next mode is selected, the LED
ring flashes and the mode selected stays lit.
The MODE sequence is as follows:
1-2-3-1-2-3-1-2…etc