17
Trouble shooting
Error Code
Likely Problems
Solution
Flash
Eve is detecting a potential
dripping tap, or slow system leak.
Find the dripping tap, or system leak, and repair.
Once the issue has been identified and resolved,
the pump should be isolated from the mains for
1 minute, then reconnected, to reset the lockout.
Steady
A drip or system leak has been
found. Protection has been
initiated, and the pump has
locked out.
Flash
EVE is detecting aeration or water
starvation in pump chambers.
Find the restriction on input flow, or air leak, and
repair. Once the issue has been identified and
resolved, the pump should be isolated from the
mains for 1 minute, then reconnected, to reset the
lockout.
Steady
Excessive aeration or water
starvation has been found.
Protection has been initiated,
and the pump has locked out.
Flash
EVE is regulating the motor speed
in order to cool, and maintain
pump performance.
Find the reason for the pump overheating, and
allow to cool. Once the issue has been identified
and resolved, the pump should be isolated from the
mains for 1 minute, then reconnected, to reset the
lockout.
Steady
An issue with overheating has
been found. Protection has been
initiated, and the pump has locked
out.
Flash
Mains Voltage input, the mains
input is varying beyond pump
limits, or the mains has been
disconnected.
Find the reason for the variation in mains inlet
voltage, and repair.
Steady
There is a motor fault. Either a
restriction or blockage of the
motor.
Possible restriction to the impeller, contact
PumpWise 0191 516 2002
x203623_salamander_p2_lh.indd 17
14/02/2019 13:04