13
EVE installed above the hot water cylinder
These numbers relate to figure 2.
1.
All up and over pipe work must be vented at the highest point on the outlet of the pump.
2.
The pump should be fitted at least 600mm below the base of the cold water tank.
3.
An anti-gravity loop at least 400mm in depth MUST BE fitted to all systems where the
pump is mounted above the hot outlet from the cylinder.
4.
Vents and other services
5.
A 22mm NO STOP ESSEX flange with dip pipe and bird beak end to limit air being drawn
into the pump, is the best option where the pump is mounted above the hot outlet from
the cylinder.
Before you finish
Commissioning
• First flush inlet pipework and carefully
fill pump with water by discharging
water from the outlet flexible hose into a
container
• If it is a negative head system, no flow will
naturally come from shower. In this setup
it is
CRITICAL
to do the following:
Discharge water through the pump into a
container before connecting the pump to
outlet pipework in order to ensure the air
has been discharged from inlet pipework
and pump chambers.
This will not happen
if the outlet pipework is connected to the
pump.
• Fit pump inlet filters
• Connect discharge pipework
• Check that all the pump isolating valves
are open
• Fill system. Check for leaks
• DO NOT RUN PUMP DRY – to do so will
cause irreparable damage to your pump
and will
invalidate your warranty
Operating Instructions
x203623_salamander_p2_lh.indd 13
14/02/2019 13:04
Summary of Contents for EVE
Page 1: ...1 Pump Installation and Warranty Guide ISSUE A...
Page 7: ...7 Assembling EVE 12 8 8 12 11 11 10 10 9 9...
Page 11: ...11 1 5 4 8 9 7 3 6 11 10 2 Figure 1...
Page 12: ...12 4 1 2 5 3 Figure 2...
Page 21: ...21 Notes...
Page 22: ...22 Notes...
Page 23: ...23 Notes...