3. PERIODIC MAINTENANCE
– 90 –
– 91 –
7) Tighten thus sub-assembled end cap to the housing with hex socket head bolt.
CAUTION
Install as straightly as possible so that the
shaft end does not damage journal bearing
which has been press-fit to end cap.
< Tightening torque for the hex socket head bolt >
< Tightening torque for the hex socket head bolt >
Bold size
M16 x 50L
Tightening torque
340-425 ft lb
Plug size
9 / 16 – 18 UNF
Tightening torque
40 – 70 ft lb