background image

9

• The ceramic disc should be kept clean of mineral deposits 

and other debris for optimal misting. NEVER use any sharp 

objects to clean the ceramic disc as this will damage the  

disc permanently.

• For optimum results, clean the water tank before changing 

diffuser blends.

Summary of Contents for aromaGeni

Page 1: ...Infuse your air with the vitality and well being of nature ultrasonic nebulizer atomiseur ultrasonique ...

Page 2: ...nts Benefits of Nebulizing 1 Recommended Saje Diffuser Blends 2 Product Features 3 Specifications 4 Diagram of Parts 5 Operating Instructions 6 7 Care Maintenance 8 9 Cautions 10 11 FCC IC Statements 12 13 FAQ 14 15 ...

Page 3: ...romas that elevate your well being When used with your favorite Saje diffuser blend the nebulizer srefreshingcoolmistbringsnature sgoodness into your space supporting balance and harmony Transform your surroundings with revitalizing air that s reminiscent of fresh mist off a waterfall Add the Saje diffuser blend of your choice and enjoy fresh inviting aromas any time soothing relaxing diffuser ble...

Page 4: ... Release refreshing diffuser blends Refresh Exhale Rain Forest tranquil diffuser blends Spa Spirit Mountain High After the Rain revitalizing and energizing diffuser blends Brainstorm Energy Use only Saje diffuser blends using other oils may result in malfunction ...

Page 5: ...eat free system to disperse essential oil molecules into the air May also be used as a humidifier Digitally programmed to stop automatically Energy efficient whisper quiet operation and auto shut off Operates with inner cover light on or off ...

Page 6: ...ion approx 3 hours continuous Mist Output approx 4 tsp 1 tsp or20 ml 5 ml perhouroncontinuous Settings continuousmistwithlightonoroff Light Options No LED button light inner cover LED light only Coverage Area approx 200 300 sq ft Dimensions D approx 4 x H 8 or D 108 mm x H 205 mm Net Weight approx 9 oz 249 g Main Materials Outer Cover PP Water Tank PP ...

Page 7: ...agram of parts a Outer Cover b Water Tank Cover c Air Outlet d LED Light e Maximum Water Level Line f Water Tank g Ceramic Disc h On Off Button i Power Adapter j DC Power Jack k Base 0 A B C D E F G K H I J ...

Page 8: ... 4 Add 10 15 drops depending on preference of your favorite Saje Diffuser Blend to the water 2 Remove the water tank cover operating instructions 1 2 3 Fill water tank with room temperature tap water to no higher than max water level line 1 3 cup 80 ml ...

Page 9: ...ll turn off automatically when water in water tank reaches minimum level approx 0 3 tsp OR 0 15 ml 10 Unit will turn off automatically when water in water tank reaches minimum level approx 0 3 tsp OR 0 15 ml Please note Run times and amount of water left in the tank after auto shut off will vary due to climate environment and other factors 6 Connect power adapter to DC power jack at the back of un...

Page 10: ...ptywaterfromthewatertank carefully avoiding the air outlet side If required use a clean soft damp cloth to wipe down exterior of unit Frequency of necessary cleaning is dependent upon usage and types of diffuser blends used ie how thick the essential oils are in the diffuser blend To clean inside water tank dispense a few drops of rubbing alcohol into tank and wipe with a clean soft cloth To clean...

Page 11: ...pt clean of mineral deposits and other debris for optimal misting NEVER use any sharp objects to clean the ceramic disc as this will damage the disc permanently For optimum results clean the water tank before changing diffuser blends ...

Page 12: ...le or attempt to repair unit in the event of a problem please contact 1 877 ask Saje When moving the device hold securely by the base Do not touch the highly sensitive ceramic disc with bare fingers Always place the unit on a stable level surface Do not fill water tank directly from tap as water could spill into the internal mechanism and cause damage Do not plug the unit into the wall socket with...

Page 13: ...in it must be able to dissipate the heat properly Use only Saje diffuser blends other oils may contain fragrances base oils or synthetics that could result in malfunction Some single note essential oils are also too thick or heavy for use in the nebulizer See FAQs for more information In case of smoke unusual aroma undue noise or other malfunction unplug the unit immediately and discontinue use Fu...

Page 14: ... of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a partic...

Page 15: ...ications not expressly approved by Saje Natural Wellness Canada could void the user s authority to operate this equipment This device complies with Part 18 of the FCC Rules and ICES 001 Although this product is tested and complies with FCC it may interfere with other devices If this product is found to interfere with another device separate the other device and this product Conduct only the user m...

Page 16: ... the water tank ensure that the water tank is filled to the maximum water level line Thewaterlevelmaybetoohigh higherthanthemaximum water level line pour out excess water and try again The ceramic disc may require cleaning Please see Care Maintenance instructions Q what type of water should go into my nebulizer To prevent damage to the unit it s recommended to use room temperature tap water To pre...

Page 17: ...ssential oils may have a thick or heavy consistency that can clog the nebulizer and cause it to stop working Saje diffuser blends have been carefully blended to be effectiveforyou andsafeandeasytouseinyournebulizer Imported and distributed by Importé et distribué par saje natural wellness 22 east 5th ave vancouver bc canada v5t 1g8 saje com 1 877 ask saje sajewellness made by our friends in china ...

Reviews: