37.
Press the keyboard button TX, and then the button DUMMY LOAD.
38.
Activate the handset key.
39.
When the tune lamp extinguishes, press the keyboard buttons SEND ALARM and TEST ALARM
simultaneously.
40.
The transmitter sends the alarm tone signal to the dummy load, which can be seen on the AE-
current meter.
41.
The alarm tones will be heard in the handset earpiece.
42.
Press the keyboard button ENT.
43.
The transmitter stops transmitting.
44.
As a final test, make a call to a coast station.
3.10 SELECTION AND DESCRIPTION OF THE SERVICE PROGRAMMES
3.10.1 HOW TO SELECT A SERVICE PROGRAMME
In order to help the operator, and the service engineer during installation or repair, the RE2100 has some
built-in service programmes.
The RE2100 has a service mode, which is activated by pressing the keyboard buttons 1 and 0
simultaneously. The display of the RE2100 will now show ‘SP-’.
The various service programmes can now be selected by keying-in a three digit number. The display of
the RE2100 will then show ‘SP-XX-X’.
A new service programme may be chosen after the keyboard button ENT has been pressed once. The
display shows ‘SP-’ again, and a new three digit number can be keyed-in.
In order to return to normal operation mode, press the keyboard button TUNE/CLARIF.
3.10.2 DESCRIPTION OF SERVICE PROGRAMMES
SP-00-X TEST OF PROCESSOR, KEYBOARD AND DISPLAY MODULE
When 00 has been keyed-in, the RX display shows ‘SP-00-’, and the programmes 0 to 3 and 8 may be
selected.
SP-00-0 READ OUT OF SOFTWARE VERSION NUMBER
In the TX display a 4 digit number will be read out, possibly followed by a letter. The number indicates
S. P. Radio’s internal software number and the letter indicates the software release.
Ex. 1085E => C-number C1085 and rel. E.
SP-00-1 READS OUT WHICH ITU FREQUENCY TABLE IS USED
When P-91 is read out, an earlier ITU table is used. When A-91 is read out, the ITU table in force from
1st June 1991 is used.
When keying-in the digit 0 or 1, the read out will be changed from A-91 to P-91 or P-91 to A-91 respectively.
SP-00-2 STARTS TEST OF THE DISPLAY
This test programme is used in the performance check, section 3.5.1.1.
When pressing <ENT> during the test, the test procedure stops. When pressing <ENT> again, the
programme steps forward. When pressing <0>, the programme continues again automatically.
Summary of Contents for RE2100
Page 1: ...S P RADIO A S AALBORG DENMARK TECHNICAL MANUAL FOR COMPACT HF SSB RE2100...
Page 2: ......
Page 4: ......
Page 6: ......
Page 8: ......
Page 18: ......
Page 20: ......
Page 30: ......
Page 35: ...3 SERVICE RE2100 PAGE 3 5 DIAGRAM TESTBOX...
Page 94: ......
Page 98: ......
Page 100: ......
Page 108: ...PAGE 5 8 5 CIRCUIT DESCRIPTION AND SCHEMATIC DIAGRAMS RE2100...
Page 112: ...PAGE 5 12 5 CIRCUIT DESCRIPTION AND SCHEMATIC DIAGRAMS RE2100...
Page 122: ...PAGE 5 22 5 CIRCUIT DESCRIPTION AND SCHEMATIC DIAGRAMS RE2100...
Page 125: ...PAGE 5 25 5 CIRCUIT DESCRIPTION AND SCHEMATIC DIAGRAMS RE2100...
Page 128: ...5 CIRCUIT DESCRIPTION AND SCHEMATIC DIAGRAMS RE2100 PAGE 5 28...
Page 131: ...5 CIRCUIT DESCRIPTION AND SCHEMATIC DIAGRAMS RE2100 PAGE 5 31...
Page 134: ...PAGE 5 34 5 CIRCUIT DESCRIPTION AND SCHEMATIC DIAGRAMS RE2100...
Page 136: ...PAGE 5 36 5 CIRCUIT DESCRIPTION AND SCHEMATIC DIAGRAMS RE2100...
Page 140: ...5 CIRCUIT DESCRIPTION AND SCHEMATIC DIAGRAMS RE2100 PAGE 5 40...
Page 144: ...PAGE 5 44 5 CIRCUIT DESCRIPTION AND SCHEMATIC DIAGRAMS RE2100...
Page 148: ......
Page 155: ...RE2100 CONTENTS 7 PARTS LIST...
Page 156: ......