26
English
Changing the lamp
The projector will detect the lamp life itself. It will show you a warning
message “ Lamp is running out of standard lifetime. Be sure to replace the lamp
as soon as possible.” When you see this message, change the lamp as soon as
possible.
Make sure the projector has been cooled down for at least 30 minutes before
changing the lamp.
Warning:
Lamp compartment is hot! Allow it to cool down before
changing lamps!
CAUTION!
DO NOT DEFEAT THIS INTERLOCK
High temperature cool for at least 30 minutes. High pressure lamp may explode if
improperly handled. Disconnect power before changing lamp.
Replace only with OSRAM GmbH, MODEL VIP R120/P16 rated 120 W.
n
o
p
Lamp module
Warning:
To reduce the risk of
personal injury, do not drop the
lamp module or touch the lamp
bulb. The bulb may shatter and
cause injury if it is dropped.
Lamp Changing Procedure:
1. Turn off the power to the projector by
pressing the Power/Standby button.
2. Allow the projector to cool down at
least 30 minutes.
3. Disconnect the power cord.
4. Use screwdriver to remove the screw
from the cover (see
n
).
5. Remove the cover (see
o
).
6. Remove the 3 screws from the
lamp module (see
p
).
7. Pull out the lamp module.
To replace the lamp module,
reverse the previous steps.
SAGEM may require that lamps replaced under warranty are returned
to SAGEM. Otherwise, contact your local waste disposal agency for the
address of the nearest deposit site.