O p e r a t i o n s a n d I n s t r u c t i o n M a n u a l
53
S A G E M E T E R I N G , I N C .
REV. 03-SIE/SRE
5. Press Select/Set to toggle back to the Analysis
Menu
6. Shortcut back to Flow Mode, see Example 2
Example 5:
How to View High Flow Rate and its Date
and Time stamp
1. Verify that meter is in Flow Mode (see Example 2)
2. If not, refer to Example 2
3. Press Flow/Shift five times (brings up Analysis
Menu)
4. Press Forward/Up five times
5. Press Select/Set, (brings up Highest Flow Rate
that the meter “has seen” since the last “Clear
Data”
6. Press Forward/Up, (displays the Time stamp of
the Highest Flow)
7. Press Forward/Up, (displays the Date stamp of
the Highest Flow)
8. Press Select/Set to toggle back to the Analysis
Menu
9. Shortcut back to Flow Mode, see Example 2
Example 6:
How to View the Meter’s Full Scale (Max Val)
1. Verify that meter is in Flow Mode
2. If not, refer to Example 2
3. Press Flow/Shift two times (brings up Display
Options Menu)
4. Press Forward/Up twice (brings up Max Val
Items)
5. Press Select/Set to bring Up Max Val (corre-
sponds to 20mA)
6. Press Select/Set to toggle back to the Display
Options Menu
7. Shortcut back to Flow Mode, see Example 2
Example 7:
How to Change from SCFM to SCFH
1. Refer to Example 3, Steps 1–7 to enter Passcode
2. The Main Menu will appear
3. Press Flow/Shift three times to bring up Eng’g
Units Menu
4. Press Back/Down three times (brings up Hour)
5. Press Select/Set to accept
6. Shortcut back to Flow Mode, See Example 2.
Example 8:
Configuring for a Specific Pipe
For this example, assume you have a single channel
meter (Channel A only) that is calibrated for
0–25,000 SFPM of Compressed Air
For example, to use the meter in a 4" pipe, follow the
steps below (assume keypad)
1. Refer to Example 3, Steps 1 -7 to enter Passcode
2. Use Flow/Shift Key to bring up Flow Basics Menu
(Press Flow/Shift twice until you cycle to that
Menu)
3. Press Forward/Up twice until Pipe Area item
appears
4. Select Set to go into numeric entry
5. Change pipe area from 1.000 to 0.0884 (see
Probe Insertion Guidelines for the pipe area for a
4" pipe which is .0884 sq ft)
6. Use Flow/Shift or Select/Set Button to move cur-
sor to left or right until the Flow Basics Menu
reappears on top line
7. Press Flow/Shift key to bring up next menu
which is Engineering Units (assume you want
units of SCFH)
8. Use the Forward/Up key and select Select/Set SCF
9. Use the Forward/Up key (or Back/Down key) and
select Select/Set Hour
10. Shortcut out (Hold Forward/Up key then toggle
Flow/Shift key)
11. Follow Probe Insertion Guidelines to insert the
meter into center of a 4" pipe
Summary of Contents for SIE Series
Page 2: ......
Page 6: ......
Page 7: ...Section GETTING STARTED A ...
Page 8: ......
Page 23: ...Section STYLES AND FEATURES B ...
Page 24: ......
Page 28: ......
Page 29: ...Section DRAWINGS C ...
Page 30: ......
Page 39: ...Section USER INTERFACE D ...
Page 40: ......
Page 58: ......
Page 59: ...Section DIAGNOSTICS E ...
Page 60: ......
Page 63: ...Section WARRANTIES AND SERVICE WORK F ...
Page 64: ......
Page 69: ...G Section APPENDIX G ...
Page 70: ......