14
Troubleshooting
POSSIBLE
PROBLEM
EASY SOLUTION
“Low Water Level” error
screen appears
• Ensure the water level is above the MIN water line.
“No Water Detected”
error screen appears
• Ensure the impeller and the foot has been inserted correctly and the water
level is above the MIN water line.
“Tilt Alert” error screen
appears
• Ensure the clamp has been installed correctly and the unit is mounted
upright.
“Move Detected” error
screen appears
• Ensure the unit has been fitted securely in the clamp and the clamp
is installed against the vessel correctly.
“Impeller Overload”
error screen appears
• Remove the foot and impeller, clearing out any foreign objects from the
heating tube, impeller and foot. Inspect the foot and impeller for any
damage or breakage.
“Unit unplugged mid-
cook…” error screen
appears
• The unit will return to the original temperature setting, consider if the cook
that was underway is still safe for consumption.
"Fault detected"
error screen appears
repeatedly
• Return the unit to a service centre or service agent for your region.
“High Temperature
Detected” error screen
appears
• Ensure the water flow from beneath the unit is unobstructed and the water
level is above the MIN water line but below the MAX water line and any
scale build up has been removed. Never wrap over the touchscreen
of the unit.
My unit is not heating
• The unit always runs a 40 second priming cycle before the heater is turned
on, wait until the unit has finished its priming cycle before the heater turns
on.
My unit does not get to
temperature
• The unit has been tested to be able to heat a 45L vessel with a secure
lid up to 90°C (194°F). If using aluminium foil or similar covering, ensure
to never wrap over the touchscreen of the unit.
The temperature on
my unit is fluctuating
rapidly
• Ensure the water flow from beneath the unit is unobstructed and the water
level is above the MIN water line but below the MAX water line.
There is a whirring or
strange noise coming
from my unit
• Remove the foot and impeller, clearing out any foreign objects from the
heating tube, impeller and foot. Inspect the foot for any damage. Inspect
the impeller for damage or breakage.
My bags are sucked up
by the water inlet
• Secure the bags to the vessel using bulldog clips.
Summary of Contents for PolyScience HydroPro Plus GSV750
Page 15: ...the HydroPro Plus the HydroPro GSV750 GSV700 DE KURZANLEITUNG...
Page 33: ...the HydroPro Plus the HydroPro GSV750 GSV700 FR GUIDE RAPIDE...
Page 49: ...the HydroPro Plus the HydroPro GSV750 GSV700 NL SNELSTARTGIDS...
Page 66: ...18 Opmerkingen...
Page 67: ...the HydroPro Plus e the HydroPro GSV750 GSV700 IT GUIDA RAPIDA...
Page 83: ...the HydroPro Plus y the HydroPro GSV750 GSV700 ES GU A R PIDA...
Page 98: ...16 Notas...
Page 99: ...the HydroPro Plus e the HydroPro GSV750 GSV700 PT MANUAL R PIDO...
Page 115: ...17 Notes...