![background image](http://html2.mh-extra.com/html/saft/4579/4579_component-maintenance-manual-with-illustrated-parts-list_3399673048.webp)
SAFT AMERICA INC.
COMPONENT MAINTENANCE MANUAL
4579
24-31-05
PAGE 602
Jan 30/98
(2)
Replace o-ring and torque lower terminal nut per Figure 801.
B.
When inspection reveals electrolyte leakage from the cell at the vent hole opening,
replace the defective O-ring (4) as follows:
(1)
Using the vent-valve wrench (P/N 093382-000), loosen and remove the vent
valve (3) from the cell assembly (2).
(2)
Cover the cell with a damp, clean cloth to prevent any foreign particles from
falling into the cell.
(3)
Remove the defective O-ring (4) from the vent valve (3), and install a new O-
ring (4) onto the vent valve (3).
(4)
Remove the cloth from the cell, and insert the vent valve (3) into the cell
assembly (2). Using the vent valve wrench (P/N 093382-000), tighten the vent
valve securely in place. To ensure they are tightened properly, use only finger
pressure on the wrench.
(5)
Clean cell assembly (2) in accordance with CLEANING.
3.
Physical damage
When necessary, remove minor dents in the battery cover (8) and battery case (7) using a hard
rubber mallet. Polish out minor pits or scratches using a fine grain abrasive porous cloth.