![background image](http://html2.mh-extra.com/html/saft/4579/4579_component-maintenance-manual-with-illustrated-parts-list_3399673020.webp)
SAFT AMERICA INC.
COMPONENT MAINTENANCE MANUAL
4579
24-31-05
PAGE 102
Jan 30/98
N E W O R
F R O M
S T O R A G E
C H A R G E
A D J U S T
E L E C T R O L Y T E
A L L C E L L S
>1.50V
A N Y C E L L
<1.50V
I N I T I A L
D I S C H A R G E
C A P A C I T Y T E S T
G O O D
N O - G O O D
R E S T
1 0 - 1 2 H R S .
C H A R G E
A D J U S T
E L E C T R O L Y T E
S P E C I A L
T E S T I N G
*
R E M O V E D
F R O M
A I R C R A F T
I N I T I A L
D I S C H A R G E
R E S I D U A L
D I S C H A R G E
R E C H A R G E
S E C O N D
D I S C H A R G E
G O O D
N O T G O O D
C H A R G E
L E V E L
E L E C T R O L Y T E
R E T U R N T O
S E R V I C E
S P E C I A L
T E S T I N G
*
A L L C E L L S
>1.50V
A N Y C E L L
<1.50V
A L L C E L L S
>1.50V
A N Y C E L L
<1.50V
*
N O T E S : Record all discharge data in battery log book.
*
= R e e n t r y p o i n t f r o m S P E C I A L T E S T I N G
I N S U L A T I O N
C H E C K
P L A C E I N
S E R V I C E
I N S U L A T I O N
C H E C K
C H E C K C E L L N U T
T O R Q U E
P G 8 0 1
C H E C K C E L L N U T
T O R Q U E
P G 8 0 1
C H E C K C E L L N U T
T O R Q U E
P G 8 0 1
C H E C K C E L L N U T
T O R Q U E
P G 8 0 1
C O N T I N U E
A T R E S I D U A L
D I S C H A R G E
U N D E R
“ R E M O V E D
F R O M A I R C R A F T ”
Note: All procedures are found in Testing and Fault Isolation
Test Procedure Flow Diagram
Figure 102