SAFT AMERICA INC.
COMPONENT MAINTENANCE MANUAL
4579
24-31-05
PAGE 101
Jan 30/98
TESTING AND FAULT ISOLATION
1.
General
This section contains battery functional tests and fault isolation information. Test procedures
are written in a step-by-step format following Fig 102. Fault isolation information is
presented in chart form (Fig 106).
NOTE:
All ( ) part identification numbers herein are IPL, Fig 1 item numbers.
2.
Required Test Equipment
NOTE
:
Test equipment having equivalent specifications can be used.
NOMENCLATURE
APPLICATION
DC Power Supply, regulated,
35 Vdc 0-60A minimum
Testing / Fault Isolation
Precision Multi-meter,
(pre0.5%),
0-2 V, 0-5 V, and 0-50 V scales
required
Testing / Fault Isolation
DC Load Bank (0-60A Minimum)
Testing / Fault Isolation
Thermometer, Immersion
Testing / Fault Isolation
Megohmmeter 250 Vdc
Testing / Fault Isolation
Required Test Equipment
Figure 101