FAULT
POSSIBLE CAUSE
REMEDY
Cell with swollen case
Cell operated with low
electrolyte level,
deterioration of separator
and damaged plates
Replace with new SAFT cell
(DISASSEMBLY, ASSEMBLY)
Cell with zero voltage when
battery circuit is open
Short circuited cell
Replace with new Saft cell
(DISASSEMBLY, ASSEMBLY)
Low insulation resistance
Leakage of electrolyte
Disassemble and clean battery
(DISASSEMBLY AND
CLEANING)
Check electrolyte level (TESTING
and FAULT ISOLATION)
Fault Isolation
Figure 106 (Page 5 of 5)