background image

WARNING

This is a design compatible component for a comprehensive 

SAFEWAZE

 Personal Fall Arrest or Fall Restraint System. Each 

component includes an instruction manual. These instructions must be 

provided to the user of this equipment prior to use. AS A USER, YOU 

MUST READ, UNDERSTAND AND FOLLOW THE MANUFACTURER’S 

INSTRUCTIONS, LABELS AND WARNINGS for each component part of 

the complete system before using it. If you do not understand the 

Instruction, Labels and Warnings for the use and maintenance of this 

component, have them explained to you. ANY MISUSE OF THIS 

COMPONENT, ANY ALTERATION OR MODIFICATION OF IT, OR 

FAILURE TO PROPERLY FOLLOW THESE USER’S INSTRUCTIONS, 

MAY RESULT IN SERIOUS INJURY OR DEATH. 

WARNING

This is an engineered system that requires trained and competent 

personnel to install.  It is understood that qualified personnel is going to 

install this system.  Because SAFEWAZE™ cannot verify that installation 

will be conducted by a “competent” person per OSHA standards, 

SAFEWAZE™

 can no longer assume the liability for the installation, or 

any liability arising due to failure to install properly.

FS-EX330-LERF

PORTABLE LEADING EDGE ROOF REACH

INSTRUCTIONS

Summary of Contents for FS-EX330-LERF

Page 1: ...nd maintenance of this component have them explained to you ANY MISUSE OF THIS COMPONENT ANY ALTERATION OR MODIFICATION OF IT OR FAILURE TO PROPERLY FOLLOW THESE USER S INSTRUCTIONS MAY RESULT IN SERI...

Page 2: ...ystem is held in place at the work location by 4 retractable jacks Two 12 Rubber on cast 360 swivel wheels and two 12 rigid rubber on cast wheels make moving the unit simple and quick The unit is comp...

Page 3: ...imum rated load for the energy absorbing lanyard SRL The lanyard shall be capable of limiting the fall arrest load to less than 1800 lbs and the SRL shall be capable of limiting the fall arrest load t...

Page 4: ...Preferably fall arrest equipment like this should when not in use be kept in dedicated cabinets which permit adequate ventilation System Label Prior to accessing the systems the user should always in...

Page 5: ...n time the anchorages should be placed so that the potential for entangling the vertical lifelines is minimal Care should also be used in selecting a harness Harnesses with sewn down back pads can lim...

Page 6: ...quipped with side d rings If it is these may be attached to for this type of work Always ensure that the locking mechanism of the snap hook or karabiner is properly closed and incapable of accidental...

Page 7: ...ner The typical attachment between a user and a single point anchor that is located at the height of the user or lower is via a lanyard See Figure 3 below for an example using a d ring which should ha...

Page 8: ...mation refer to the Self Retracting Lifeline Instruction Guide in the operation and maintenance manual To attach to the SRL pull the tag line down This will pull the SRL snap hook down to you Slip the...

Page 9: ...o be sure that it is firm and that roll out is not possible see Figure 1 above If a d ring extender is used the extender is connected to the back d ring of the harness attach the snap hook at the end...

Page 10: ...nimum installation distance from the side of the unit to the leading edge is 3 ft Anchorage loading is designed such that the angle between the overhead single point attachment on the Roof Reach to th...

Page 11: ...Part numbers and Assembly Identification 6 7 THE UNIT MUST SIT ON A CLEAN AND DRY SURFACE FRONT JACK FEET SHOUD BE AT LEAST 1 FOOT FROM ROOF EDGE...

Page 12: ...gning the holes in the back of the arm assembly with the holes in the front of the mast assembly and pin in place with two pins Step 4 Raise mast assembly until the hole in the bottom of the mast asse...

Page 13: ...front and rear assembly and pin in place using one pin Step 7 Pull pins from body front and body rear assembly at the wheels and telescope outriggers out until the far holes on the outriggers line up...

Page 14: ...ll four leveling jacks until the wheels of the unit are off the surface Using the level located on the body front assembly make sure the unit is level Step 10 Attach SRLs to the loop connections at th...

Page 15: ...A 1926 502 regulations Warning Failure to read and follow product instructions could result in serious personal injury or death Training and instruction review should be repeated at regular intervals...

Page 16: ...els Attention labels located on the Arm of the Roof Reach system Deployment warning located on the body of the Roof Reach system Counterweight warning located on the back of the unit between the pushi...

Page 17: ...Contact Information SAFEWAZE 322 Industrial Court Concord NC 28025 Phone 704 262 7893 Fax 262 262 9051 Email info safewaze com www safewaze com...

Page 18: ...rm water and a mild detergent Ensure that the parts are rinsed thoroughly with plenty of clean water Although highly resistant to chemicals and environmental conditions take all precautions to avoid c...

Page 19: ...del No Mfg Date SAFEWAZE 704 262 7893 Date Condition of System Inspected By Maintenance 1 Inspect all hardware for distortion and deformation Check for visible cracks excessive wear and tear corrosion...