background image

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Iron Trapper™ Iron, Hydrogen Sulfide & Manganese Filter Installation Overview 

General:

  When installing a water softener and a filter together, always install the filter first.  Be sure to test the water 

since you will need this information to properly program the control valve. 

 

Installation procedures  

 

1.

 

Locate the main water line, and install the unit before the water heater and near 
a 110 volt power source.   

2.

 

Install a water check valve on the inlet side of the filter (not supplied). 

3.

 

Determine where the drain is to be located and install the drain using ¾” or 1” 
PVC or ½” drain line tubing.  If ½” tubing is used do not extend the length past 
15 feet, which may restrict the flow. 

4.

 

Close inlet and outlet on the valve. 

5.

 

Program the valve for your specific application (see below). 

6.

 

Put the valve into a manual regeneration to make sure the cycles are functioning 
correctly.  (Press “regen” to advance to each individual  cycle.) 

7.

 

Start-up in 

backwash 

(with inlet and outlet closed). 

8.

 

Open the inlet slowly.  Once water runs to drain, open the inlet fully. 

9.

 

Continue backwash until the drain water runs clear.  (This may take some time.) 

10.

 

 Advance to the 

draw 

cycle (to create an air pocket in the filter tank). 

11.

 

The 

2

nd

 backwash

 should be turned “OFF”. 

12.

 

The 

rinse

 cycle should be turned “OFF”.

 

 

13.

 

For the 

refill

 cycle, set the salt level at “ZERO” to deactivate this cycle. 

14.

 

When the valve goes into service, open outlet on the valve to supply water to  
the house.  

 

Valve Programming  

 

Safety Zone Water® Signature Series electronic control valve 

 

The Safety Zone Signature Series valve is highly versatile, and can be 
programmed for water softeners, Combo softener / Filter systems 
and “air draw” Iron and Sulfur filters.   Valves are available in 1”, 1-
1/4”, 1-1/2” and 2” sizes.  Residential tank sizes include 10x54 (1 
cube); 12x52 (2 cube) and 14x65 (3 cube).  Standard components 
include air draw valve, by-pass valve; upper basket; riser tube;  
bottom distributor; drain line flow control button, media and gravel 
under bedding for even flow distribution. 

Valve Settings

 

 

 
 

System 

 

Media 

(Cu. Ft.) 

 

Tank Size 

 

Backwash 

#1 

 

Draw 

 

 

Backwash 

#2 

 

Rinse 

 

Refill 

Salt (lbs.) 


 
 

R

 Regen 

Days

 

ISF-150-AD 

10x54 

20 

MINUTES 

60 

MINUTES 

OFF 

OFF 

ZERO 

1 (high Iron) 

2 (low Iron) 

Note: Settings may be adjusted depending in water source, Iron, Hydrogen Sulfide and Manganese content. 

-2- 

 

Summary of Contents for Iron Trapper ISF-150-AD

Page 1: ... By pass valve Included Specifications How it works The Iron Trapper utilizes oxygen contained in your water and fresh ambient air injected inside the filter tank to oxidize Iron Hydrogen Sulfide and Manganese so they drop out of solution to form particles These particles are trapped by the filter media and are periodically removed from the filter during the backwash cycle Iron Trapper systems do ...

Page 2: ...ue backwash until the drain water runs clear This may take some time 10 Advance to the draw cycle to create an air pocket in the filter tank 11 The 2nd backwash should be turned OFF 12 The rinse cycle should be turned OFF 13 For the refill cycle set the salt level at ZERO to deactivate this cycle 14 When the valve goes into service open outlet on the valve to supply water to the house Valve Progra...

Page 3: ...to complete a water test prior to start up and valve programming Check the following parameters Hardness pH Iron well water Hydrogen Sulfide well water Manganese if common in the area System placement 1 Locate main water line and determine where to place the unit near power outlet and location for the drain 2 Install system on main water line before the water heater Be sure the by pass is closed I...

Page 4: ...y 1 3 to fill mineral tank 4 Allow air to escape listen until spurting stops 5 When water flows from drain open inlet valve fully 6 Make sure drain line is not restricted Note Do not tee drain line with a softener 7 Continue backwash until water runs clear 8 Press and release REGEN to advance to the DRAW cycle to create an air pocket in the filter tank 9 Press and release REGEN to advance to the 2...

Reviews: