Iron Trapper™ Iron, Hydrogen Sulfide & Manganese Filter Installation Overview
General:
When installing a water softener and a filter together, always install the filter first. Be sure to test the water
since you will need this information to properly program the control valve.
Installation procedures
1.
Locate the main water line, and install the unit before the water heater and near
a 110 volt power source.
2.
Install a water check valve on the inlet side of the filter (not supplied).
3.
Determine where the drain is to be located and install the drain using ¾” or 1”
PVC or ½” drain line tubing. If ½” tubing is used do not extend the length past
15 feet, which may restrict the flow.
4.
Close inlet and outlet on the valve.
5.
Program the valve for your specific application (see below).
6.
Put the valve into a manual regeneration to make sure the cycles are functioning
correctly. (Press “regen” to advance to each individual cycle.)
7.
Start-up in
backwash
(with inlet and outlet closed).
8.
Open the inlet slowly. Once water runs to drain, open the inlet fully.
9.
Continue backwash until the drain water runs clear. (This may take some time.)
10.
Advance to the
draw
cycle (to create an air pocket in the filter tank).
11.
The
2
nd
backwash
should be turned “OFF”.
12.
The
rinse
cycle should be turned “OFF”.
13.
For the
refill
cycle, set the salt level at “ZERO” to deactivate this cycle.
14.
When the valve goes into service, open outlet on the valve to supply water to
the house.
Valve Programming
Safety Zone Water® Signature Series electronic control valve
The Safety Zone Signature Series valve is highly versatile, and can be
programmed for water softeners, Combo softener / Filter systems
and “air draw” Iron and Sulfur filters. Valves are available in 1”, 1-
1/4”, 1-1/2” and 2” sizes. Residential tank sizes include 10x54 (1
cube); 12x52 (2 cube) and 14x65 (3 cube). Standard components
include air draw valve, by-pass valve; upper basket; riser tube;
bottom distributor; drain line flow control button, media and gravel
under bedding for even flow distribution.
Valve Settings
System
Media
(Cu. Ft.)
Tank Size
Backwash
#1
Draw
Backwash
#2
Rinse
Refill
Salt (lbs.)
R
R
Regen
Days
ISF-150-AD
1
10x54
20
MINUTES
60
MINUTES
OFF
OFF
ZERO
1 (high Iron)
2 (low Iron)
Note: Settings may be adjusted depending in water source, Iron, Hydrogen Sulfide and Manganese content.
-2-