Air check valve

 

 

Notice an air check valve is installed on the “air draw” 
valve. This will prevent air escaping from the tank. 
 

Drain line installation 

Proper installation of the drain line is critical to any Iron and 
Sulfur filter’s performance. For best results use rigid ¾” PVC. 

 

If ½” drain line tubing is used, do not extend the tubing 
more than fifteen feet. 

 

Never restrict a drain line by combining a filter drain with a 
softener drain.   

 

The backwash requirement for the Iron Trapper is 7.5 GPM. 

Water test 

It is essential to complete a water test, prior to start-up and valve programming.

 

Check the following parameters:

 

 

 

Hardness

 

 

pH

 

 

Iron (well water)

 

 

Hydrogen Sulfide (well water)

 

 

Manganese (if common in the area)

 

 

 

 

 

System placement 

 

1.

 

Locate main water line and determine where to place the unit (near power outlet and location 
for the drain). 

 

 

 

 

2.

 

Install system on main water line before the water heater.

 

Be sure the by-pass is closed. If a filter is to be installed, install it before the softener.

 

 

 

-3- 

 

3/4” rigid PVC drain is highly recommended. 

To set clock 

 

SET CLOCK

 – Press 

SET CLOCK

 at any time to set hour and minutes, then press 

“NEXT”

 to exit.  The clock is a 

24 hour clock, so AM or PM must be set accordingly. (Make adjustments when “hour” or “minutes” blink.) 
 

Summary of Contents for Iron Trapper ISF-150-AD

Page 1: ... By pass valve Included Specifications How it works The Iron Trapper utilizes oxygen contained in your water and fresh ambient air injected inside the filter tank to oxidize Iron Hydrogen Sulfide and Manganese so they drop out of solution to form particles These particles are trapped by the filter media and are periodically removed from the filter during the backwash cycle Iron Trapper systems do ...

Page 2: ...ue backwash until the drain water runs clear This may take some time 10 Advance to the draw cycle to create an air pocket in the filter tank 11 The 2nd backwash should be turned OFF 12 The rinse cycle should be turned OFF 13 For the refill cycle set the salt level at ZERO to deactivate this cycle 14 When the valve goes into service open outlet on the valve to supply water to the house Valve Progra...

Page 3: ...to complete a water test prior to start up and valve programming Check the following parameters Hardness pH Iron well water Hydrogen Sulfide well water Manganese if common in the area System placement 1 Locate main water line and determine where to place the unit near power outlet and location for the drain 2 Install system on main water line before the water heater Be sure the by pass is closed I...

Page 4: ...y 1 3 to fill mineral tank 4 Allow air to escape listen until spurting stops 5 When water flows from drain open inlet valve fully 6 Make sure drain line is not restricted Note Do not tee drain line with a softener 7 Continue backwash until water runs clear 8 Press and release REGEN to advance to the DRAW cycle to create an air pocket in the filter tank 9 Press and release REGEN to advance to the 2...

Reviews: