ENGLISH V. 4.04
LED 1 indicates the power supply status:
Continuous green -
Mains power supply OK.
Flashing red -
Battery-operated, with power to the
emergency light.
Continuous red -
Battery-operated, no power to the
emergency light.
LED 2 indicates alarm and battery condition:
Light off -
Battery OK.
Continuous red -
Battery test failure.
Flashing red -
Rapidly fl ashing Yellow -
Battery check in progress.
Active alarm not reset.
Calling out in progress.
LED 3 indicates the phone line’s status:
Continuous red -
No SIM-card or network (when using
GSM).
Flashing red -
No telephone line connected.
Searching for GSM-network.
Audio self test failed.
Flashing green -
Telephone line connected.
GSM-network OK.
Flashing yellow -
Incoming call.
Flashing green -
Call connection in progress.
Continuous green -
Call connected.
Reset button
Hold for 4 sec -
Show GSM signal strenght.
Press 3 times -
Start a battery service test
Press once -
Reset active alarm.
FRONT PANEL
LED 1
LED 2
LED 3
Reset button
Colour code
Signal strenght
3 Green
100%
2 Green, 1 Yellow
86%
1 Green, 2 Yellow
71%
3 Yellow
57%
1 Red, 2 Yellow
29%
2 Red, 1 Yellow
15%
3 Red