23
© 2011 SafeLine and all the SafeLine products and accessories are copyrighted by law.
Programming
ENGLISH V. 4.04
OTHER CODES
CODE
DATA
COMMENTS
Local button
*85*
- #
Used if car stations has built in alarm button.
0 = OFF (Default)
1 = ON
Break on new alarm
*86*
- #
Disconnects a call longer than 60 seconds at new activation of the alarm
button and calls the next emergency call number.
0 = OFF
1 = ON (Default)
Alarm button delay time
*87*
- - #
Delay time from pressing the alarm button until activating the alarm.
00-25 seconds. Default = 10.
Outputs.
*88*
- #
0 = Standard (Default)
• Relay 1 will be activated when set time reached.
• Relay 1 will be deactivated when emergency call ends.
• Relay 2 will be activated when the battery test has failed.
• Relay 2 will be deactivated by pressing the reset button.
1 = EN81-28 Pictograms
• Relay 1 will be activated when the emergency button in pressed
(yellow pictogram).
• Relay 1 will be deactivated when the reset button is pressed or if alarm
centre presses “5”.
• Relay 2 will be activated when the call is acknowledged (green
pictogram).
• Relay 2 will be deactivated when the call is disconnected.
2 = DTMF-controlled
The relays can be activated remotely for 5 seconds.
• Relay 1 will be activated for 5 seconds when DTMF “8” is pressed.
• Relay 2 will be activated for 5 seconds when DTMF “9” is pressed.
3 = Manual - ECF
• Relay 1 will be activated when set delay reached.
• Relay 1 will be deactivated when the reset button is pressed.
Change password
*91*
- - - - #
Change password (default=0000)
Simulate an alarm event
*94*
- #
Triggers an alarm event after programming is terminated.
1 = Emergency call
2 = Test alarm
3 = Battery failure
4 = Microphone/Loudspeaker failure
5 = Emergency call
6 = Maintenance
7 = Main unit power failure
Reset to default settings
*99*
- #
1 = Factory default
2 = Default P100(The following codes will be set):
*21*0#, *22*0#, * 27*03#, *80*1#, *84*1#, *88*1#
3 = Default CPC(The following codes will be set):
*21*3#, *22*3#, *27*03#, *80*1#, *84*1#, *88*1#
4 = Default VOICE(The following codes will be set):
*21*1#, *22*1#, * 27*03#, *80*1#, *84*1#, *88*1#
Compatability mode
*77*
- #
0=Automatic voice switching
The call is validated when there is a voice response. The call is terminated
by pressing ”#”.
1=Kone ECII (lift telephone)
When there is a voice response, some ascending tones will be heard. The
call is validated by pressing ”4”. The call is terminated by pressing ”0”.
The call is terminated without reciept notifi cation by pressing ”2”(the unit
will call the next number).
2=Manual voice switching
When there is a voice response, some ascending tones will be heard. The
call is validated by pressing ”4”. Unit is still in automatic mode. To enter
manual mode and talk press ”*”. To listen press ”7”. Go back to automatic
mode press ”4”. The call is terminated by pressing ”#”.
It is possible to enter manual voice switching mode although the unit is
programmed as automatic by pressing ”*”. No ascending tones will be
heard.