Programming

ENGLISH V. 4.04

OTHER CODES 

CODE

DATA

COMMENTS

Local button

*85*

- #

Used if car stations has built in alarm button.
0 = OFF (Default) 
1 = ON

Break on new alarm

*86*

- #

Disconnects a call longer than 60 seconds at new activation of the alarm 
button and calls the next emergency call number.
0 = OFF 
1 = ON (Default)  

Alarm button delay time

*87*

- - #

Delay time from pressing the alarm button until activating the alarm.
00-25 seconds. Default  = 10.

Outputs.

*88*

- #

0 = Standard (Default)

•  Relay 1 will be activated when set time reached.
•  Relay 1 will be deactivated when emergency call ends.
•  Relay 2 will be activated when the battery test has failed.
•  Relay 2 will be deactivated by pressing the reset button. 

1 = EN81-28 Pictograms

• Relay 1 will be activated when the emergency button in pressed 

(yellow pictogram).

•  Relay 1 will be deactivated when the reset button is pressed or if alarm 

centre presses “5”.

• Relay 2 will be activated when the call is acknowledged (green 

pictogram).

•  Relay 2 will be deactivated when the call is disconnected.

2 = DTMF-controlled
The relays can be activated remotely for 5 seconds.

•  Relay 1 will be activated for 5 seconds when DTMF “8” is pressed.
•  Relay 2 will be activated for 5 seconds when DTMF “9” is pressed.

3 = Manual - ECF

•  Relay 1 will be activated when set delay reached.
•  Relay 1 will be deactivated when the reset button is pressed.

Change password

*91*

- - - - #

Change password (default=0000)

Simulate an alarm event

*94*

- #

Triggers an alarm event after programming is terminated.
1 = Emergency call
2 = Test alarm
3 = Battery failure
4 = Microphone/Loudspeaker failure
5 = Emergency call
6 = Maintenance
7 = Main unit power failure

Reset to default settings

*99*

- #

1 = Factory default
2 = Default P100(The following codes will be set): 
*21*0#, *22*0#, * 27*03#, *80*1#, *84*1#, *88*1#
3 = Default CPC(The following codes will be set):  
*21*3#, *22*3#, *27*03#, *80*1#, *84*1#, *88*1#
4 = Default VOICE(The following codes will be set):  
*21*1#, *22*1#, * 27*03#, *80*1#, *84*1#, *88*1#

Compatability mode

*77*

- #

0=Automatic voice switching
The call is validated when there is a voice response. The call is terminated 
by pressing ”#”.
1=Kone ECII (lift telephone)
When there is a voice response, some ascending tones will be heard. The 
call is validated by pressing ”4”. The call is terminated by pressing ”0”. 
The call is terminated without reciept notifi cation by pressing ”2”(the unit 
will call the next number).
2=Manual voice switching
When there is a voice response, some ascending tones will be heard. The 
call is validated by pressing ”4”. Unit is still in automatic mode. To enter 
manual mode and talk press ”*”. To listen press ”7”. Go back to automatic 
mode press ”4”. The call is terminated by pressing ”#”. 

It is possible to enter manual voice switching mode although the unit is 
programmed as automatic by pressing ”*”. No ascending tones will be 
heard.

Summary of Contents for 3000

Page 1: ...SafeLine 3000 Installation manual ENGLISH V 4 04 02 2011 PATENT PENDING Emergency telephone for lifts Complies to EN81 28 and EN81 70 standards...

Page 2: ...200 mA Emergency light Emergency light output 12V max 0 5A Acoustic emergency signal output 12 VDC max 0 5A Inputs 10 30 Volts 5 mA Optically isolated Relay outputs Max 2A 30V DC 0 5A 125V AC potenti...

Page 3: ...Wiring diagram round cable 12 Wiring diagram SafeLine 3000 on PSTN line 14 Activating the SIM card 15 Mounting 16 Programming interfaces 17 Programming method 18 Programming unit numbers 19 Programmin...

Page 4: ...pect to the buyer of this product or to third parties for damage loss costs or work incurred as a result of accidents misuse of the product incorrect installation or illegal changes repairs or additio...

Page 5: ...ower Battery status PSTN GSM Net Call in out progress 4 RS232 PC connection For firmware update and programming 5 Slot for optional extra station card Two supplementary microphone speaker units can be...

Page 6: ...ine Connect telephone line here 3 GSM antenna connection SMA Fixed to the battery holder refer to item 10 on the previous page 4 SIM card holder 5 Volume controls For the extra remotes Turn right to i...

Page 7: ...100 130 90 54 101 25 8 4 x n 4 2 Installation ENGLISH V 4 04 SafeLine 3000 Main unit Article number SL3000 SL3000 GSM Flush mount car station Article number SLRem_V2 Flush mount car station with emerg...

Page 8: ...unt car station Article number SLRem_V3 Surface mount car station with emergency light Article number SLRem_V3Led Surface mount car station with pictograms Article number SLRem_V3Pic Surface mount car...

Page 9: ...rom the car 1 Input 1 signal coming from the car 1 Input 2 signal coming from the car 1 Inputs not in use or coming from the machine room 0 MOUNTED ON CAR TOP WIRES IN TRAVELLING CABLE SafeLine 3000 P...

Page 10: ...7 8 A B C D E 1 2 Installation ENGLISH V 4 04 ORANGE BATTERY GRAY BLACK BLUE GREEN GREEN YELLOW BROWN YELLOW 12 V 12 V 12 V AT ALARM 12 V AT ALARM EM BUTTON NO NC ACOUSTIC SIGNAL 230 VAC 0 V 0 V RED...

Page 11: ...stallation ENGLISH V 4 04 GRAY GRAY Extra remote board ORANGE ORANGE BLACK BLACK RED RED SPEAKER SPEAKER SPEAKER SPEAKER MIC MIC MIC MIC MIC MIC MIC MIC WIRING DIAGRAM FLAT CABLE EMERGENCY LIGHT EXTRA...

Page 12: ...E 1 2 Installation ENGLISH V 4 04 ORANGE BATTERY ORANGE WHITE GREEN WHITE BROWN WHITE BLUE WHITE GREEN YELLOW BROWN GREEN 12 V 12 V 12 V AT ALARM 12 V AT ALARM EM BUTTON NO NC ACOUSTIC SIGNAL 230 VAC...

Page 13: ...4 04 ORANGE ORANGE Extra remote board ORANGE WHITE ORANGE WHITE GREEN WHITE GREEN WHITE BLUE BLUE SPEAKER SPEAKER SPEAKER SPEAKER MIC MIC MIC MIC MIC MIC MIC MIC WIRING DIAGRAM ROUND CABLE EMERGENCY L...

Page 14: ...ELEKTRONIK AB 2008 WWW SAFELINE SE COPYRIGHT HISSELEKTRONIK AB 2008 WWW SAFELINE SE COPYRIGHT HISSELEKTRONIK AB 2008 WWW SAFELINE SE COPY RIGHT HISSE LEKTR ONIK AB 2008 WWW SAFE LINE SE Installation E...

Page 15: ...ings menu change the PIN code to 0000 If this is not possible set the PIN code to 1234 or set the PIN code request option to OFF Might not always function 2 Verify the PIN code by switching your phone...

Page 16: ...AB 2008 WWW SAFELINE SE 1 5 m 1 5 m 1 5 m Installation ENGLISH V 4 04 Mounting PSTN board GSM board Adding an extra station board MOUNTING To avoid GSM interference Place the main unit the stations a...

Page 17: ...ion or on site after installation with a programming cable from us Remote programming For remote programming you can use any PSTN tone dial phone Dial the phone number of the SafeLine 3000 Enter the f...

Page 18: ...nected to phone line Press unit nr 1 9 repeatedly untill 3 beeps Enter the password yes No Yes Wrong password One long beep If the time between the operation of two keys exceeds 10 seconds the code ha...

Page 19: ...in unit numbers can be remotely programmed Remotely program unit numbers in SafeLines connected in series yes no Dial phone number Hang up Hang up Re dial the phone number Program unit as number 1 Pro...

Page 20: ...nd phone number to emergency call centre to 45645687 Phone number for test alarm Send test alarm every third day Test alarm protocol to P100 Alarm button delay to 10 seconds PROGRAMMING EXAMPLE 1 Star...

Page 21: ...CPC Change this only if your alarm operator is using any of the mentioned protocols Call type 2nd number 22 Call type 3rd number 23 Call type 4th number 24 Call type LMS number 30 LMS Lift Monitoring...

Page 22: ...ptions for the recorded message from lift car 62 0 Disable recorded message 1 Enables recorded message 62 Play the the recorded message Options for the recorded message from top of car 63 0 Disable re...

Page 23: ...lay 1 will be activated when set delay reached Relay 1 will be deactivated when the reset button is pressed Change password 91 Change password default 0000 Simulate an alarm event 94 Triggers an alarm...

Page 24: ...alarm not reset Calling out in progress LED 3 indicates the phone line s status Continuous red No SIM card or network when using GSM Flashing red No telephone line connected Searching for GSM network...

Page 25: ...ashing once every 5 seconds Unit is OK Flashing two times every 5 seconds Alarm filter activated Green steady Call connected Yellow LED Call in progress The Yellow Pictogram LED is lit as soon as the...

Page 26: ...valid telephone line connected Connect a telephone to the RJ12 connector on the front of the SafeLine 3000 All LEDs are off No tone No reaction No connection LED 3 flashes red 5 times Long tone in th...

Page 27: ...04 EMERGENCY CALLING PROCESS Alarm operator made connection Calling 1st phone number Wait 1 minute Calling 2nd phone number Calling 4th phone number Calling 3rd phone number Answer Line missing or bus...

Page 28: ...Making calls like with a normal fixed line phone also GSM 3 Emergency calls to pre programmed numbers at the press of the alarm button 4 Receiving incoming calls 5 Test alarms at preset intervals 6 Se...

Page 29: ...by law 0 0 3 2 1 0 8 5 2 1 7 4 0 9 6 3 Operating ENGLISH V 4 04 INTERCOM BETWEEN MACHINE ROOM AND CAR PIT TOP OF CAR Press 0 to dial external telephone number Press 1 to call the lift car Press 2 to c...

Page 30: ...button is pressed 3 times within 2 seconds an automatic battery test will be performed The battery test takes about 20 minutes To cancel the battery test disconnect all power If the battery is low the...

Page 31: ...ty Volume might be set too loud Lower the volume and check again Interfering noise when the call is connected If the main unit is installed on the car roof the problem might be due to induction in the...

Page 32: ...00 Brussels BELGIUM Tel 32 0 2 762 98 10 Fax 32 0 2 762 97 10 E mail order safeline eu SafeLine Deutschland Westfalenstra e 22a D 51688 Wipperf rth DEUTSCHLAND Tel 49 0 2267 8 67 96 63 Fax 49 0 2267 8...

Reviews: