Using this test, an administrator can scan for working access points, check their
operating frequency, encryption, see signal/noise levels and view either device has
enabled W-Jet or not.
An administrator can use this feature to identify a clear channel to set the device to that
will not receive interference from adjacent working devices.
(!) Note that Site Survey function can take several minutes to perform.
To perform the Site Survey test currently, click the Start scan button:
Start scan - click to perform the Site Survey test.
Show only W-Jet AP - select this option to sort Site Survey results.
3.3 Link
Test
(!) We recommend ensuring that there is no traffic on the link before running the Link
Test as results may not be completely accurate.
Use the Link test tool to check the quality of the established point-to-point link. This tool
tests the throughput at selected packet sizes and iterations. Link test can be run from
either the Remote unit or Local unit. Results represent the maximum, minimum and
average value of the performed test.