Saf-Fro DIGISTEEL III 320C Operation And Maintenance Instructions Download Page 11

 

 

DIGISTEEL

 

III

 

320C

 

/

 

DIGIPULS

 

III

 

320C

 

Create and save a program

These paragraphe explains how to create, modify and save a welding program.

1)

 

Activate program management mode SETUP 

2)

 

Set your program with commutators then long push on button OK

3)

 

Screen displays message as following:

 

 

NOTE

 : The 

DIGISTEEL III 320C

 

 / DIGIPULS III 320C

The locking key entered has to be written in order to desactivate the function lock. 
  

3.3.5. Program call with trigger 

 
This function allows to chain from 2 to 10 programs. This function is available in 4T welding mode
 

Program chaining

 : 

The function program call works with programs from P50 to P99 by ten.

 

P50

P59 ; P60

P69 ; P70

P79 ; P80

Selec first program with which you want to begin your chain. Then during welding, each time you will push trigger
To chain less than ten programs, in the program following end of loop desired put a different parameter (As syne
It is possible to setup time of trigger push to detect change of program chain : SETUP 
 

Example

: Create a program list from P50 to P55 (6

1)

 

In program P56, put different welding c

2)

 

Select program P50 (First program for start of welding

3)

 

Start welding 

4)

 

Each time trigger will be pushed, power source will change program until P55. 

 

 

 

Function selection: 

rEC

: Save program 

Ld

: Load program 

cod

: Activate locking 

code 

Cancel action in 
progress. 

320C 

 

dify and save a welding program. Hereunder is explained the common menu used.

Activate program management mode SETUP 

 PGM 

 put YES 

 exit SETUP 

Set your program with commutators then long push on button OK 
Screen displays message as following: 

 

/ DIGIPULS III 320C

 allows to lock program menu. This function is available on program screen with the parameter cod. 

The locking key entered has to be written in order to desactivate the function lock.  

from 2 to 10 programs. This function is available in 4T welding mode only and program management mode has to be activated

with programs from P50 to P99 by ten. 

P79 ; P80

P89 ; P90

P99 

Selec first program with which you want to begin your chain. Then during welding, each time you will push trigger, program will change.

program following end of loop desired put a different parameter (As synergy or welding cycle).

It is possible to setup time of trigger push to detect change of program chain : SETUP 

 CPT 

 put value from 1 to 100 

: Create a program list from P50 to P55 (6 programs). 

lding cycle or synergy than P55 in order to finish chain 

Select program P50 (First program for start of welding 

Each time trigger will be pushed, power source will change program until P55. When chain is finished, power source will restart to P50.

EN  

11

 

/

 

28 

Hereunder is explained the common menu used. 

 

 

 

 

allows to lock program menu. This function is available on program screen with the parameter cod.  

only and program management mode has to be activated 

program will change. 

rgy or welding cycle). 

put value from 1 to 100 

 exit SETUP 

When chain is finished, power source will restart to P50. 

Program number 
selection.from 

P01

 to 

P99

P00

: Cancel program 

mode 

Validate action in 
progress 

Summary of Contents for DIGISTEEL III 320C

Page 1: ...II 320C EN SAFETY INSTRUCTIONS FOR OPERATION AND MA Cat n 8695 1259 Rev A Date 03 2016 DIGISTEEL III 320C DIGIPULS III 320C FOR OPERATION AND MAINTENANCE Contact http www airliquidewelding com DIGISTE...

Page 2: ...EN Arc welding and plasma cutting may be dangerous for the operator and persons close to the work area Read the operating manual...

Page 3: ...ONNECTION 2 8 SWITCH ON 3 INSTRUCTIONS FOR USE 3 1 FRONT PANEL FUNCTIONS 3 2 CALIBRATE THE POWER SOURCE 3 3 DYSPLAY AND USE 4 OPTIONS ACCESSORIES 5 MAINTENANCE 5 1 GENERAL 5 2 ROLLERS AND WIRE GUIDE 5...

Page 4: ...ptions refer to the instructions supplied with the option WARNING The plastic handles are not intended for slinging the set Stability of the equipment is 1 2 DIGISTEEL III 320C ALLATION is a manual we...

Page 5: ...onnection Protection index Insulation class Standard WARNING This power source cannot be used in falling rain or snow It may be stored outside but it is not designed for without protection during rain...

Page 6: ...r serve que l imp dance de r seau public d alimentation basse tension au point de couplage commun soit inf rieure ce mat riel est conforme la CEI 61000 3 11 et la CEI 61000 3 12 et peut tre connect au...

Page 7: ...ersion and recognized power 320C The following wires are used in reverse polarity SD ZN SAFDUAL ZN feeder unit 5 and ensure that it can not fall Insert the spool of wire on the axis Make sure that the...

Page 8: ...gas wire diameter and type of welding wire 2 3 4 7 1 DIGISTEEL III 320C Left display Voltage Right display Current wire speed wire thickness 1 for selection of welding mode 2 welding mode Button canc...

Page 9: ...ess the OK button to access the COnFIG Setup parameter with the left hand encoder and select On with the right hand encoder Press the OK button on the front panel The display unit indicates triGEr con...

Page 10: ...ing display no Software update mode no Factory settings reset Pressing YeS will cause a reset of the parameters to factory defaults when exit SETUP menu List of accessible parameters in CYCLE menu Def...

Page 11: ...ivate program management mode SETUP PGM put YES exit SETUP Set your program with commutators then long push on button OK Screen displays message as following DIGIPULS III 320C allows to lock program m...

Page 12: ...ff welding Adjust arc voltage during welding and out off welding 3 TROLLEY II NEW VERSION R f W000383000 It enables to easily move the power source in a worshop environment DIGISTEEL III 320C welding...

Page 13: ...ith watercooler option W000345075 PROMIG NG 441W 3 M W000345076 PROMIG NG 441W 4 M W000345077 PROMIG NG 441W 5 M W000274865 PROMIG NG 450W 3 M W000274866 PROMIG NG 450W 4 M W000274867 PROMIG NG 450W 5...

Page 14: ...emove dust and metal particles accumulated between the magnetic circuits and the windings of the transformer Work must be performed using a plastic tip to avoid damage to the insultation of the windin...

Page 15: ...onents REFERENCE DESIGNATION W000386033 FANS 24VDC 80X25 QTY 2 W000386036 FRONT PANEL DIGISTEEL III 320C W000386038 FRONT PANEL DIGIPULS III 320C W000386040 TRANSPARENT PLASTIC COVER W000386041 AUXILI...

Page 16: ...16 28 DIGISTEEL III 320C EN 320C DIGIPULS III 320C...

Page 17: ...DIGISTEEL III 320C DIGIPULS III 320C Internal and inverter 320C EN 17 28...

Page 18: ...18 28 Front and rear DIGISTEEL III 320C EN 320C DIGIPULS III 320C...

Page 19: ...TEEL III 320C DIGIPULS III 320C that can be directly purchased from your local provider REFERENCE DESIGNATION W000373703 DUST FILTER W000278018 LOT OF 2 SCREWS FOR ROLLER W000277338 ROLLER ADAPTOR GUI...

Page 20: ...SSAGE E25 C Let the generator cool down The fault disappears by itself after several minutes Make sure that the inverter fan works DISPLAY OF THE MESSAGE E33 MEM This message indicates that the memory...

Page 21: ...power supply phases OTHER Wire stuck in the molten pool or at the contact tube Optimise the arc extinction parameters PR spray and post retract message when turning the power on The TtriG message is...

Page 22: ...22 28 5 7 ELECTRICAL DIAGRAM EN DIGISTEEL III 320C DIGIPULS III 320C...

Page 23: ...source arc great reduction in spatter when welding carbon steels resulting in a very significant reduction in finishing costs It improves the appearance of the weld bead thanks to improved wetting of...

Page 24: ...tortions at high welding currents in the typical globular welding range Reduce the amount of spatter compared to the globular mode reduce smoke emissions compared with the usual modes up to 25 less pr...

Page 25: ...in the general Cycle submenu of the SETUP It enables starting the welding with slope enables weld bead finish with a decreasing level of welding Pulling the trigger the first time activates the pre ga...

Page 26: ...all positions but has the disadvant causing more spatters DIGISTEEL III 320C gas and turns on the welding current Releasing the trigger causes the welding to stop slope and sequencer settings is disab...

Page 27: ...or instance when welding thin sheet metal such this mechanism c SHORT ARC 0 6 mm 0 8 mm 1 mm ATAL 5 ATAL 5 ATAL 5 ARCAL 14 ARCAL 14 ARCAL 14 ARCAL 21 ARCAL 21 ARCAL 21 CO2 CO2 NOXALIC 12 NOXALIC 12 AR...

Page 28: ...LSE 0 8 mm 1 mm ARCAL 14 ARCAL 14 ARCAL 21 ARCAL 21 NOXALIC 12 NOXALIC 12 ARCAL 121 ARCAL 121 ARCAL 12 ARCAL 12 ARGON ARGON ARGON PULSE 0 6 mm 0 6 mm ARGON ARGON ARGON ARGON NOTE For any other synergi...

Reviews: