3. TRANSPORT, HANDLING AND INTERMEDIATE STORAGE
Lifting
Never lift the pump by means of its electric cable, but use the special handle.
The electric pumps have to be lifted observing the following recommendations, according to their weight
(indicated on their packing): Up to 20 kg: manually by one person; From 20 to 60 kg: manually by two persons;
More than 60 kg: by means of a suitable lifting device.
Storing and preservation
If the pump/electropump remains inactive at low temperatures (the water inside the pump could freeze and
cause serious damage) or, at any rate, for a period exceeding three months, it is a good idea to empty the
pump and protect it by applying suitable products to its surfaces.
To empty the liquid, see the chapter 8.
4. TECHNICAL SPECIFICATIONS AND USE
Identification of the product
The identification data and technical characteristics of the pump/electropump are shown on the plate attesting
to its conformity to CE standards (fig.1).
Description of the product
Submersible drainage electric pumps SDLV-TEX SDLV-TEXD.
Technical specifications
Pump type
SDLV-TEX – SDLV-TEXD
Impeller
Vortex
Motor
Asynchronous - single or three-phase
Protection degree
IP 68
Insulation class
F
Standard electric feeding
Tension
(220-240) / (380-415) / (600-720) V
Frequency
50 Hz
Electric cable type
H07RN-F
Hydraulic seals
Mechanical
Bearings greasing
Standard permanent grease
Temperature of the liquid
max 40
°
Permitted ambient conditions
Non explosive atmosphere
Permitted maximum pressure
6 bar
Performances
Capacity up to 33m
3
/h – Head up to 14 m
Frequency of the starts
Installed power (kW) Up to 22 kW
Start/ hour (2-pole motors) 15
Sounding pressure level
Sounding pressure level (dBA)
Installed power (kW)
61
0,75
61
1,1
63
1,5
Use
Never use the electric pump in explosive atmospheres or to pump inflammable or dangerous liquids.
Never use the electric pump for liquids to be consumed in human feeding.
In order to avoid seriously damaging the components, observe the following recommendations:
-
never use the pump in absence of liquid;
-
never use the pump out of the water;
-
never use the pump with null delivery (closed delivery);
-
do not immerse the pump under 20 m;
-
always use the pump with a delivery indicated in the working diagram.
Characteristics of the liquids to be pumped
- PH between 6
÷
7.7 - Density not higher than 1 kg/dm3 and viscosity equal to the water one
- Temperature max 40
°
C - Quantity of solid bodies in suspension max 1%
- Dimension of solid bodies in suspension: SDLV-TEX 20 mm; SDLV-TEXD 4 mm;
The bodies in suspension shall not be excessively abrasive and they shall not be characterised by shapes
tending to agglomerate.