3.   TRANSPORT, HANDLING AND INTERMEDIATE STORAGE

Lifting
Never lift the pump by means of its electric cable, but use the special handle.
The electric pumps have to be lifted observing the following recommendations, according to their weight
(indicated on their packing):  Up to 20 kg: manually by one person; From 20 to 60 kg: manually by two persons;
More than 60 kg: by means of a suitable lifting device.

Storing and preservation
If the pump/electropump remains inactive at low temperatures (the water inside the pump could freeze and
cause serious damage) or, at any rate, for a period exceeding three months, it is a good idea to empty the
pump and protect it by applying suitable products to its surfaces.

To empty the liquid, see the chapter 8.

4.   TECHNICAL SPECIFICATIONS AND USE

Identification of the product
The identification data and technical characteristics of the pump/electropump are shown on the plate attesting
to its conformity to CE standards (fig.1).

Description of the product

Submersible drainage electric pumps SDLV-TEX   SDLV-TEXD.

Technical specifications

Pump type

SDLV-TEX – SDLV-TEXD

Impeller

Vortex

Motor

Asynchronous - single or three-phase
Protection degree

IP 68

Insulation class

F

Standard electric feeding

Tension

(220-240) / (380-415) / (600-720) V

Frequency

50 Hz

Electric cable type

H07RN-F

Hydraulic seals

Mechanical

Bearings greasing

Standard permanent grease

Temperature of the liquid

max 40

°

Permitted ambient conditions

Non explosive atmosphere

Permitted maximum pressure

6 bar

Performances

Capacity up to 33m

3

/h – Head up to 14 m

Frequency of the starts

Installed power (kW)                    Up to 22 kW
Start/ hour (2-pole motors)          15

Sounding pressure level

Sounding pressure level (dBA)

Installed power (kW)

61

0,75

61

1,1

63

1,5

Use

Never use the electric pump in explosive atmospheres or to pump inflammable or dangerous liquids.
Never use the electric pump for liquids to be consumed in human feeding.
In order to avoid seriously damaging the components, observe the following recommendations:
-

never use the pump in absence of liquid;

-

never use the pump out of the water;

-

never use the pump with null delivery (closed delivery);

-

do not immerse the pump under 20 m;

-

always use the pump with a delivery indicated in the working diagram.

Characteristics of the liquids to be pumped
- PH between 6

÷

7.7                              - Density not higher than 1 kg/dm3 and viscosity equal to the water one

- Temperature max 40

°

C                     - Quantity of solid bodies in suspension max 1%

- Dimension of solid bodies in suspension: SDLV-TEX 20 mm;  SDLV-TEXD 4 mm;

The bodies in suspension shall not be excessively abrasive and they shall not be characterised by shapes
tending to agglomerate.

Summary of Contents for SDLV-TEX

Page 1: ...Manual de empleo y mantenimiento Manuel de emploi et de entretien Betriebs und wartungsanleitung Manual de utiliza o e manuten o ELETTROPOMPE SOMMERSE SUBMERSIBLE ELECTROPUMPS ELECTROBOMBAS SUMERGIBL...

Page 2: ...ectropompes s rie SDLV TEX SDLV TEXD Directiva Compatibilidade electromagn tica 2014 30 EU est o conformes s Directiva M quinas 2006 42 EC SDLV TEX SDLV TEXD Directive RoHS 2011 65 EU 2015 863 EU KONF...

Page 3: ...li non citati nel presente manuale DICHIARAZIONE DI CONFORMITA 2 1 GENERALITA 3 2 SICUREZZA ED AVVERTENZE ANTINFORTUNISTICHE 3 3 TRASPORTO MOVIMENTAZIONE ED IMMAGAZZINAMENTO INTERMEDIO 4 4 CARATTERIST...

Page 4: ...ione elettrica standard Tensione 220 240 380 415 600 720 V Frequenza 50 Hz Cavo elettrico tipo H07RN F Tenute idrauliche Meccaniche Lubrificazioni cuscinetti Standard a grasso permanente Temperatura d...

Page 5: ...non possa essere ripristinata Il quadro e tutta l apparecchiatura elettrica relativa devono essere eseguiti in osservanza delle norme CEI EN 60204 1 E responsabilit dell installatore assicurarsi che...

Page 6: ...mpianto elettrico attendere che la temperatura del liquido sia tale da non creare pericolo di bruciature se il liquido trattato dalla pompa nocivo per la salute indispensabile osservare le seguenti av...

Page 7: ...s or directions not mentioned in this manual must be taken into consideration as well DECLARATION OF CONFORMITY 2 1 GENERAL INFORMATION 7 2 SAFETY INFORMATION 7 3 TRANSPORT HANDLING AND INTERMEDIATE S...

Page 8: ...c feeding Tension 220 240 380 415 600 720 V Frequency 50 Hz Electric cable type H07RN F Hydraulic seals Mechanical Bearings greasing Standard permanent grease Temperature of the liquid max 40 Permitte...

Page 9: ...from being reconnected The board and all relative electric equipment shall be manufactured according to CEI EN 60204 1 directives The installer shall verify that the plant complies with the safety ru...

Page 10: ...t the pump motor from the electrical system wait until the temperature of the liquid is such not to create a danger of burns if the liquid handled by the pump is harmful for one s health it is indispe...

Page 11: ...cales no citados en este manual DECLARACI N DE CONFORMIDAD 2 1 GENERALIDAD 11 2 INFORMACI N SOBRE LA SEGURIDAD 11 3 TRANSPORTE DESPLAZAMIENTO Y ALMACENAMIENTO INTERMEDIO 12 4 ESPECIFICACIONES T CNICAS...

Page 12: ...tecci n IP 68 Clase de aislamiento F Alimentaci n el ctrica est ndar Tensi n 220 240 380 415 600 720 V Frecuencia 50 Hz Cable el ctrico tipo H07RN F Juntas hidr ulicos Mec nicos Lubricaci n cojinetes...

Page 13: ...lquier trabajo quite la corriente y aseg rese que no pueda ser reactivada El cuadro y todo el equipo el ctrico correspondiente deben cumplir con las normas CEI EN 60204 1 El instalador es responsable...

Page 14: ...sperar a que la temperatura del l quido no ocasione peligro de quemaduras si el l quido tratado por la bomba es nocivo para la salud ser indispensable cumplir las siguientes advertencias el operador d...

Page 15: ...EN GARDE CONTRE LES ACCIDENTS DU TRAVAIL 15 3 TRANSPORT MANUTENTION ET STOCKAGE INTERM DIAIRE 16 4 SPECIFICATIONS TECHNIQUES ET UTILISATIONS 16 5 INSTALLATION 17 6 MISE EN MARCHE FONCTIONNEMENT ET MI...

Page 16: ...nsion 220 240 380 415 600 720 V Fr quence 50 Hz C ble lectrique type H07RN F Garnitures hydrauliques M caniques Lubrification des roulements Standard la graisse permanente Temp rature du liquide max 4...

Page 17: ...t tout l quipement lectrique doivent tre r alis s conform ment aux normes CEI EN 60204 1 L installateur doit v rifier que l installation soit conforme aux prescriptions techniques de s curit en vigueu...

Page 18: ...it tre r cup r avec soin et limin conform ment aux r glementations en vigueur la pompe doit tre lav e l int rieur et l ext rieur en liminant les r sidus suivant les indications ci dessus V rifier le n...

Page 19: ...glichkeit haben jeder zeit in der Anleitung nachzusehen Vor Durchf hrung jeder Art von Ma nahme an der Maschine muss die gesamte Gebrauchs und Wartungsanleitung unbedingt sorgf ltig gelesen werden Des...

Page 20: ...bis zu 14 m Starth ufigkeit Installierte Leistung kW Bis zu 22 kW Starts Stunde 2 polige Motoren 15 Schalldruckpegel Installierte Leistung kW Schalldruckpegel dBA 61 0 75 61 1 1 63 1 5 Einsatz Verwen...

Page 21: ...chalttafel und alle zugeh rigen elektrischen Ger te m ssen unter Einhaltung der Normen CEI EN 60204 1 erstellt werden Es geh rt zur Verantwortlichkeit des Installateurs sich davon zu berzeugen dass di...

Page 22: ...ssigkeit so weit verringert hat dass keine Verbrennungsgefahr mehr besteht ist die von der Pumpe gef rderte Fl ssigkeit gesundheitssch dlich sind die folgenden Hinweise zu beachten der Bediener muss e...

Page 23: ...manual de uso e manuten o DECLARA O DE CONFORMIDADE 2 1 GENERALIDADE 23 2 ADVERT ENCIAS CONTRA INFORT NIOS 23 3 TRANSPORTE MOVIMENTA O E ARMAZENAMENTO INTERM DIO 24 4 CARACTER STICAS T CNICAS E UTILIZ...

Page 24: ...ica padr o Tens o 220 240 380 415 600 720 V Frequ ncia 50 Hz Cabo el ctrico tipo H07RN F Juntas hidr ulicas Mec nicas Lubrifica o rolamentos Padr o com graxa permanente Temperatura do l quido M X 40 C...

Page 25: ...fique se de que n o possa ser restabelecida O quadro e todo o aparelho el ctrico referente devem ser executados observando as normas CEI EN 60204 1 Fica sob a responsabilidade do instalador certificar...

Page 26: ...a temperatura do l quido se arrefe a o suficiente para n o provocar queimaduras Se o l quido tratado pela bomba for nocivo para a sa de indispens vel observar as seguintes advert ncias o operador dev...

Page 27: ...27 Fig 1 Fig 2 Fig 3 Fig 4a Fig 4b Fig 6a Fig 6b R U1 V1 W1 S T X X X 3 N L1 PE Marrone Brown Blu Blue Nero Black Giallo Verde Yellow Green...

Page 28: ...io in cui e stato effettuato l acquisto efavorisce il riciclo dei materiali di cui composto il prodotto Per informazioni piu dettagliate inerenti i sistemi di salute smaltimento ambientalmente compati...

Page 29: ...ntor barrado por uma cruz colocado no equipamento ou na sua embalagem indica que PT Este produto est em conformidade com a Directiva WEEE 2012 19 EU Gemeinde oder im Gesch ft in demdas Ger t gekauft w...

Page 30: ...30...

Page 31: ...32...

Page 32: ...Cod 215 VI SAER is an ISO 9001 2015 Certified Company Certificate N 501003317...

Reviews: