REV01 - Aug. 06
Ideas with Passion
The system consists of a motor-
ized valve (B),
which controls air required to
froth milk along with the “Ver-
nay” valve and aeration/drainage
of milk, and a cappuccinatore (C).
The motor (1) is a stepper version and the internal micros-
witch (2) which resets the position after dispensing.
Cappuccinatore layout
a - Air inlet for frothing
b - Vernay valve
c - Milk aeration/drainage
d - Steam inlet
e - Milk outlet
f - Milk inlet
4/9
PRIMEA Section 06
1
2