REV01 - Aug. 06
Ideas with Passion
5.1.2 Microswitch and sensor check
Errors
(Errors)
Dreg drawer:
Coffee grounds drawer Micro
(Dregdraw:)
OK Drawer present
ER Drawer missing
Service:
Door microswitch
(Door:)
OK door closed
ER door open
Water tank:
Tank Micro
(WaTank:)
OK tank engaged
ER tank empty or in reserve (see diagnostics)
Water level:
Water level capacitive sensor
(WaLevel)
OK Water present
ER Water low
Drip tray:
Drip tray capacitive sensor
(DripWater:)
OK drip tray empty
ER drip tray full
Milk container:
Milk container door micro
(MilkTank)
OK milk container door closed
ER milk container door open
Cappuccinatore:
Milk con cappuccinatore micro
(CappDraw:)
OK Milk container and cappuccinatore inserted
ER milk container
Drip tray:
Drip tray micro
(no drip tray)
OK trip present
(Tray miss:)
ER no tray
Sensors
St: steam
Steam heater temperature sensor (Touch Plus only)
Number: current temperature
OK Sensor connection ok
ER sensor shorted or disconnected
Wa: water
Water heater temperature sensor
Number: current temperature
OK Sensor connection ok
ER sensor shorted or disconnected
Dregdraw:OK
Door:OK
WaTank:OK
WaLevel:OK
DripWater:OK
MilkTank:OK
CappDraw:OK
Tray miss:OK
Errors
Sensor
St:100:OK
Wa:100:OK
3/20
PRIMEA Section 05
Summary of Contents for Prime line
Page 3: ...REV01 Aug 06 Ideas with Passion SECTION 1 INTRODUCTION REV 00 PRIMEA Section 01...
Page 5: ...REV01 Aug 06 Ideas with Passion SECTION 2 TECHNICAL DATA REV 00 PRIMEA Section 02...
Page 9: ...REV01 Aug 06 Ideas with Passion SECTION 3 BRIEF INSTRUCTIONS REV 01 PRIMEA Section 03...
Page 15: ...REV01 Aug 06 Ideas with Passion SECTION 4 DIAGRAMS REV 00 PRIMEA Section 04...
Page 22: ...REV01 Aug 06 Ideas with Passion SECTION 5 TROUBLESHOOTING REV 01 PRIMEA Section 05...
Page 43: ...REV01 Aug 06 Ideas with Passion SECTION 6 OPERATING LOGIC REV 01 PRIMEA Section 05...
Page 76: ...REV01 Aug 06 Ideas with Passion SECTION 8 SERVICE SCHEDULE REV 01 PRIMEA Section 08...