AULIKA 05 FAULT FINDING
Rev. 00 / July 2012
Page / 08
04
3 Hydraulic Circuit
3 Hydraulic Circuit
EVsteam
EVwater
Pump1
EVdisch.
EVcoffee
Pump2
T1 xx
T2 yy
p/s: zz
m Capp
m Milk
m Tank
^
SECTOR
TYPE
DESCRIPTION
EVsteam
FUNCTION
If activated, it operates the 24 VDC solenoid valve of the steam circuit
(actual activation occurs only if: - the grounds drawer and the brew unit
niche drawer are assembled and the side door is closed)
EVwater
FUNCTION
If activated, it operates the 24 VDC solenoid valve of the hot water circuit
(actual activation occurs only if: - the grounds drawer and the brew unit
niche drawer are assembled and the side door is closed)
EVdisch.
FUNCTION
If activated, it operates the 24 VDC solenoid valve of the steam circuit
discharge (actual activation occurs only if: - the grounds drawer and the
brew unit niche drawer are assembled and the side door is closed)
EVcoffee
FUNCTION
If activated, it operates the 230VAC solenoid valve
Pump1
FUNCTION
If activated, it operates pump 1 of the coffee circuit
Pump2
FUNCTION
If activated, it operates pump 2 of the water/steam circuit
T1
INFO
Shows the temperature of the coffee boiler in °C
T2
INFO
Shows the temperature of the water/steam boiler in °C
p/s
INFO
Shows the water flow in the turbine at any moment, expressed in pulses
per second. When Pump 1 (coffee pump) is turned on and the 230 V so-
lenoid valve (EVcoffee) is activated the value cannot be lower than 12p/
sec. When Pump 2 (water&steam pump 2) is turned on and the discharge
solenoid valve (EVdisch) is activated the value cannot be lower than 8p/
sec.
m Capp
INFO
shows the status of the presence of the cappuccinatore unit if tur-
ned on it is active
m Milk
INFO
shows the status of the presence of the milk valve in the cappuccinatore
unit if turned on it is active
m Tank
INFO
If active, it shows that the water presence sensor in the tank is ac-
tive and water is present at least to the level of the sensor
Summary of Contents for Aulika SUP040R
Page 3: ...Rev 00 July 2012 AULIKA...
Page 8: ...Rev 00 July 2012 AULIKA...
Page 13: ...Rev 00 July 2012 AULIKA...
Page 21: ...Rev 00 July 2012 AULIKA...
Page 29: ...Rev 00 July 2012 AULIKA...
Page 38: ...Rev 00 July 2012 AULIKA...
Page 41: ...Rev 00 July 2012 AULIKA...
Page 51: ...Rev 00 July 2012 AULIKA...
Page 52: ...AULIKA 08 NOTES Rev 00 July 2012 Page 01 01...
Page 53: ...Rev 00 July 2012 AULIKA...
Page 54: ...AULIKA 09 HYDRAULIC DIAGRAM Rev 00 July 2012 Page 01 01...
Page 55: ...Rev 00 July 2012 AULIKA...
Page 56: ...AULIKA 10 ELECTRIC DIAGRAM Rev 00 July 2012 Page 01 01...