AULIKA 04 OPERATING LOGIC
Rev. 00 / July 2012
Page / 07
The temperature sensor is an NTC which, in case of excess temperatures, reduces the resistan-
ce absorption.
The electronics recognises and regulates the actual temperature of the boiler through a voltage
reduction.
Resistance values and their corresponding temperatures: see table
4.7. Temperature sensor (adjustment)
Temp. (° C) R nom (kΩ)
ΔR (+/- %)
20
61,465
8,6
50
17,599
5,9
75
7,214
4,1
80
6,121
3,7
85
5,213
3,4
90
4,459
3,1
100
3,3
2,5
125
1,653
3,9
150
0,893
5,1
4.6. Single Microswitch
The gearbox is operated by a direct current
motor that acts on the smallest double too-
thed wheel through a worm screw.
The assembly is mounted on the axle of a
large toothed wheel and, when a request for
coffee must be addressed from idle mode, it
moves to the delivery position and then goes
back to the idling position.
- Idling position: 1
- Delivery position: 2
2
1
05
Summary of Contents for Aulika SUP040R
Page 3: ...Rev 00 July 2012 AULIKA...
Page 8: ...Rev 00 July 2012 AULIKA...
Page 13: ...Rev 00 July 2012 AULIKA...
Page 21: ...Rev 00 July 2012 AULIKA...
Page 29: ...Rev 00 July 2012 AULIKA...
Page 38: ...Rev 00 July 2012 AULIKA...
Page 41: ...Rev 00 July 2012 AULIKA...
Page 51: ...Rev 00 July 2012 AULIKA...
Page 52: ...AULIKA 08 NOTES Rev 00 July 2012 Page 01 01...
Page 53: ...Rev 00 July 2012 AULIKA...
Page 54: ...AULIKA 09 HYDRAULIC DIAGRAM Rev 00 July 2012 Page 01 01...
Page 55: ...Rev 00 July 2012 AULIKA...
Page 56: ...AULIKA 10 ELECTRIC DIAGRAM Rev 00 July 2012 Page 01 01...