background image

35

English

3  - SAFETY ADVICE

The machine is to be used solely by adults who have care-

fully read and fully understood this manual and all the safety 

advice contained in the same.

The appliance is not to be used by persons (including chil-

dren) with reduced physical, mental or sensory abilities or 

with limited experience and/or expertise, unless they are 

supervised by a person responsible for their safety, or they 

are instructed by this person on how to properly use the 

appliance. 

- Children must be supervised to ensure they do not play 

with the appliance. 

- This appliance is to be used for household applications or 

in similar areas like: 

. for staff only cooking areas in shops, offices and other 

professional environments; 

. farms; 

. for clients use in hotels, motels and other residential type 

areas; 

. environments like bed and breakfasts.

The  user  is  responsible  in  relation  to  third  parties  in  the 

working area.

The installer, user and maintenance technician are obliged 

to notify the constructor of any defects or faults which may 

effect the original safety of the system.

Installation must be effected solely by authorized and qua-

lified personnel.

Do not install the appliance in a location where water jets 

may be used.

The appliance must only be installed in places where it can 

be used and maintained only by qualified staff.

The machine is to be used solely in the presence of suitable 

lighting.

For  safety  reasons,  all  worn  or  damaged  parts  must  be 

promptly replaced.

Regularly  check  that  the  power  supply  cable  is  in  good 

conditions. Damaged cables must never be repaired using 

insulating tape or clamps.

Do  not  expose  the  machine  to  the  elements  (sun,  rain  , 

etc).

Prolonged machine standstill at temperatures of under 0°C 

(zero degrees centigrade), may cause serious damage or 

breakage to the boiler piping: it is therefore necessary to 

completely empty the water circuit before every prolonged 

standstill.

The removal of guard and/or safety elements fitted on the 

machine is forbidden.

The packaging components must be consigned to special 

disposal centres and must in any event never be left unguar-

ded or within reach of children, animals or non-authorized 

persons.

The constructor declines responsibility for any damage to 

things, persons or animals caused by eventual interventions 

on the machine by personnel not specifically authorized to 

undertake such operations.

In the event of any non-authorized interventions or repairs 

on the machine, or in the event of the use of non-original 

spares all guarantee terms become void, and the company 

reserves the right to reject validity.

The user must comply with the current safety laws in force 

in  the  country  of  installation,  as  well  as  common  sense 

and ensure that all maintenance operations are regularly 

carried out.

Never clean the inside of the machine with power supply 

on and plug connected and in any event avoid the use of 

water sprays or detergents.

The user must not touch the machine if his hands or feet are 

wet or damp, neither must be use the machine in bare feet. 

Although the machine is earthed it is advisable to use woo-

den platforms or a cut-out box complying with local laws in 

order to prevent the risk of electrocution.

Summary of Contents for AROMA SM

Page 1: ...lich Espressomaschine M quina Profesional para Caf Expr s Professionele machine voor espressokoffie M quina profissional para caf expresso Modello Model Mod le Modell Modelo Modellen Modelos INSTRUCTI...

Page 2: ...misura Sezione 6 Immunit ai disturbi condotti indotti da campi a radiofrequenza EN61000 4 6 Compatibilit elettromagnetica EMC Parte 4 Tecniche di prova e misura Sezione 11 Prove di immunit a cadute d...

Page 3: ...5...

Page 4: ...s dans le pr sent manuel nous sommes certains que vous appr cierez la qualit de notre machine Nous vous prions de lire attentivement les indications contenues dans le manuel sur l utilisation correcte...

Page 5: ...ions particuli rement importantes et ou dangereuses Atenci n Operaciones particularmente importantes y o peligrosas Let op Bijzonder belangrijke en of gevaarlijke werkzaamheden Aten o Opera es particu...

Page 6: ...o reduce the coffee dispensing group temperature 40 6 6 With spouts 40 7 FUNCTION USE AND PROGRAMMING 40 7 1 Coffee measure programming 41 7 2 Tea measure programming hot water 43 7 3 Coffee delivery...

Page 7: ...details on any residual risks and all those operations which require particular care The present manual is to be considered as an integral part of the machine and must be CONSERVED FOR FUTURE REFEREN...

Page 8: ...ower supply cable is in good conditions Damaged cables must never be repaired using insulating tape or clamps Do not expose the machine to the elements sun rain etc Prolonged machine standstill at tem...

Page 9: ...ht kg 70 90 Boiler capacity L 13 21 Boiler resistance absorbed power 230 240 400 415 V 3 N W 4760 5950 ECO Max boiler resistance absorbed power 230 240 400 415 V 3 N W 3170 3950 Pump motor W 165 165 O...

Page 10: ...tion Check that the power supply cable is efficient and that it complies with national and European safety standards The user must undertake to power the machine protecting the power line using a suit...

Page 11: ...to calibrate the pressure switch as described in paragraph 6 2 In the event of a machine featuring a gas heating system it is necessary to switch on the gas by operating the gas valve 4 after operatin...

Page 12: ...ete screw turn Warning Disconnect the electricity supply before undertaking this operation fig 5 fig 6 fig 7 6 3 Pump pressure calibration Insert the filter holder into the unit filled with regularly...

Page 13: ...Disconnect group thermostat 2 Code WGADM1561 T 103 C and replace it with the lower temperature thermostat Code WGADM2067 T 93 C included in the machine equipment system supervision through alarms cont...

Page 14: ...zed as follows press key T5 of keyboard relative to group 1 and keep pressed for over 5 seconds and check that all the keyboard leds come on In which case by operating on the keyboard relative to grou...

Page 15: ...ee par 7 5 Wait until the pre infusion function is complete before stopping delivery in progress NOTE During the programming of a unit the function of the other units is deactivated as well as tea dis...

Page 16: ...ed indicators come on Press the T8 tea key within 30 seconds programming time out This begins the tea water delivery ope ration Once the required measure is obtained press T8 again to suspend water de...

Page 17: ...very from all the machine units 7 4 Continuous coffee measures For continuous coffee measure delivery press key T5 from the keyboard corre sponding to the unit on which one wishes to operate The LED c...

Page 18: ...chine Once all the water has been suctioned stop delivery by pressing key T7 Pre infusion Our software permits measure configu ration so that the relative delivery of the COFFEE measures through volum...

Page 19: ...ress key T5 again T1 KEY LED ON PRE INFUSION ON T2 KEY LED ON MIXED TEA ON T3 KEY LED ON WASHING ALARM ON 7 6 Tea delivery On pressing key T8 the corresponding solenoid valve is engaged thereby begin...

Page 20: ...4 Engagement deactivation In order to set the function on the keyboard of unit 2 for example keep key T5 pres sed down and the corresponding LED will begin flashing until the wording SERVICE OFF appe...

Page 21: ...e same way as for coffee with the only difference being that at the end of the volumetric delivery of the coffee the timed milk delivery BEGINS SEPARATELY Once the desired quantity is obtained stop de...

Page 22: ...machines equipped with display Langauge selection In order to select the consultation language on switching on press key T4 and keep pressed Press key T1 several times to select the desired language...

Page 23: ...and keep pressed for over 10 seconds The display will show the dispensing operations under taken press key T5 again to escape from this condition By pressing key T1 forward or T2 back it is possible t...

Page 24: ...ng key T1 it is possible to obtain a reading of the number of TEA dispensing operations made To cancel the totals of the individual con sumptions but not the total cumulative data press keys T3 and T4...

Page 25: ...the machine off and then on again Lack of volumetric counter impulses On starting a volumetric control coffee cycle the correct function of the volumetric counter is checked by the reading of the numb...

Page 26: ...nd shift lever from right to left as shown in fig 8 3 and allow the salted water to drain out of pipe F until the water is fresh Shift lever D from right to left as shown in fig 8 4 NB These regenerat...

Page 27: ...ee deposits which may jeopardize yield we advise that before starting work in the morning that you put filter holder D in with empty filter while machine is hot and operate the unit several times In t...

Page 28: ...ce saver engaged 4 reinsert the resistance Too much water in the boiler 1 the motor driven pump remains engaged 1 contact specialized personnel 2 perforated exchanger 2 contact specialized personnel 3...

Page 29: ...lda Hot water collection solenoid valve Magnetventil Hei wasserent nahme lectrovanne de pr l vement d eau chaude Electrov lvula toma de agua caliente Magneetventiel automatisch aftappen warm water Ele...

Page 30: ...la placa presente sobre el cable de alimentaci n Generalmente las m quinas est n predispuestas para una conexi n de estrella con neutro ELEKTRISCHE AANSLUITING Alvorens de machine op het elektricitei...

Page 31: ...r gua de deriva o B modificando as liga es indicadas no esquema ao lado Delta connection To change the connection from a star connection to a delta connection modify the connections shown in the diag...

Page 32: ...scht werden Auf dem Versorgungsklemmbrett A zwei Br cken hinzuf gen C die mitgeliefert werden und die Verbindungen sowohl auf dem Klemmbrett A als auch auf dem Klemmbrett B ndern wie es auf dem nebens...

Page 33: ...Cod WGA8003021000 Rev 06...