background image

41

English

7.1 Coffee measure programming

T1 – single espresso coffee

T2 – double espresso coffee

T3 – single long coffee

T4 – double long coffee

T5 – Programming/continuos

T6 – Cappuccino

T7 – Milk

T8 – Tea (hot water)

The measured amounts of coffee may be mo-

dified (by means of volumetric checking) and 

memorized as follows:

-  press key T5 (of keyboard relative to group 

1) and keep pressed for over 5 seconds and 

check that all the keyboard leds come on. In 

which case, (by operating on the keyboard 

relative  to  group  1)  all  the  units  will  be 

programmed, while by pressing key T5 of 

another unit, only the programming of the 

unit on which one is operating is possible.

IMPORTANT !!

 The settings made on unit 1 

(operating on the first keyboard) will be auto-

matically copied on to all the other units.

Keyboard symbols:

Summary of Contents for AROMA SM

Page 1: ...lich Espressomaschine M quina Profesional para Caf Expr s Professionele machine voor espressokoffie M quina profissional para caf expresso Modello Model Mod le Modell Modelo Modellen Modelos INSTRUCTI...

Page 2: ...misura Sezione 6 Immunit ai disturbi condotti indotti da campi a radiofrequenza EN61000 4 6 Compatibilit elettromagnetica EMC Parte 4 Tecniche di prova e misura Sezione 11 Prove di immunit a cadute d...

Page 3: ...5...

Page 4: ...s dans le pr sent manuel nous sommes certains que vous appr cierez la qualit de notre machine Nous vous prions de lire attentivement les indications contenues dans le manuel sur l utilisation correcte...

Page 5: ...ions particuli rement importantes et ou dangereuses Atenci n Operaciones particularmente importantes y o peligrosas Let op Bijzonder belangrijke en of gevaarlijke werkzaamheden Aten o Opera es particu...

Page 6: ...o reduce the coffee dispensing group temperature 40 6 6 With spouts 40 7 FUNCTION USE AND PROGRAMMING 40 7 1 Coffee measure programming 41 7 2 Tea measure programming hot water 43 7 3 Coffee delivery...

Page 7: ...details on any residual risks and all those operations which require particular care The present manual is to be considered as an integral part of the machine and must be CONSERVED FOR FUTURE REFEREN...

Page 8: ...ower supply cable is in good conditions Damaged cables must never be repaired using insulating tape or clamps Do not expose the machine to the elements sun rain etc Prolonged machine standstill at tem...

Page 9: ...ht kg 70 90 Boiler capacity L 13 21 Boiler resistance absorbed power 230 240 400 415 V 3 N W 4760 5950 ECO Max boiler resistance absorbed power 230 240 400 415 V 3 N W 3170 3950 Pump motor W 165 165 O...

Page 10: ...tion Check that the power supply cable is efficient and that it complies with national and European safety standards The user must undertake to power the machine protecting the power line using a suit...

Page 11: ...to calibrate the pressure switch as described in paragraph 6 2 In the event of a machine featuring a gas heating system it is necessary to switch on the gas by operating the gas valve 4 after operatin...

Page 12: ...ete screw turn Warning Disconnect the electricity supply before undertaking this operation fig 5 fig 6 fig 7 6 3 Pump pressure calibration Insert the filter holder into the unit filled with regularly...

Page 13: ...Disconnect group thermostat 2 Code WGADM1561 T 103 C and replace it with the lower temperature thermostat Code WGADM2067 T 93 C included in the machine equipment system supervision through alarms cont...

Page 14: ...zed as follows press key T5 of keyboard relative to group 1 and keep pressed for over 5 seconds and check that all the keyboard leds come on In which case by operating on the keyboard relative to grou...

Page 15: ...ee par 7 5 Wait until the pre infusion function is complete before stopping delivery in progress NOTE During the programming of a unit the function of the other units is deactivated as well as tea dis...

Page 16: ...ed indicators come on Press the T8 tea key within 30 seconds programming time out This begins the tea water delivery ope ration Once the required measure is obtained press T8 again to suspend water de...

Page 17: ...very from all the machine units 7 4 Continuous coffee measures For continuous coffee measure delivery press key T5 from the keyboard corre sponding to the unit on which one wishes to operate The LED c...

Page 18: ...chine Once all the water has been suctioned stop delivery by pressing key T7 Pre infusion Our software permits measure configu ration so that the relative delivery of the COFFEE measures through volum...

Page 19: ...ress key T5 again T1 KEY LED ON PRE INFUSION ON T2 KEY LED ON MIXED TEA ON T3 KEY LED ON WASHING ALARM ON 7 6 Tea delivery On pressing key T8 the corresponding solenoid valve is engaged thereby begin...

Page 20: ...4 Engagement deactivation In order to set the function on the keyboard of unit 2 for example keep key T5 pres sed down and the corresponding LED will begin flashing until the wording SERVICE OFF appe...

Page 21: ...e same way as for coffee with the only difference being that at the end of the volumetric delivery of the coffee the timed milk delivery BEGINS SEPARATELY Once the desired quantity is obtained stop de...

Page 22: ...machines equipped with display Langauge selection In order to select the consultation language on switching on press key T4 and keep pressed Press key T1 several times to select the desired language...

Page 23: ...and keep pressed for over 10 seconds The display will show the dispensing operations under taken press key T5 again to escape from this condition By pressing key T1 forward or T2 back it is possible t...

Page 24: ...ng key T1 it is possible to obtain a reading of the number of TEA dispensing operations made To cancel the totals of the individual con sumptions but not the total cumulative data press keys T3 and T4...

Page 25: ...the machine off and then on again Lack of volumetric counter impulses On starting a volumetric control coffee cycle the correct function of the volumetric counter is checked by the reading of the numb...

Page 26: ...nd shift lever from right to left as shown in fig 8 3 and allow the salted water to drain out of pipe F until the water is fresh Shift lever D from right to left as shown in fig 8 4 NB These regenerat...

Page 27: ...ee deposits which may jeopardize yield we advise that before starting work in the morning that you put filter holder D in with empty filter while machine is hot and operate the unit several times In t...

Page 28: ...ce saver engaged 4 reinsert the resistance Too much water in the boiler 1 the motor driven pump remains engaged 1 contact specialized personnel 2 perforated exchanger 2 contact specialized personnel 3...

Page 29: ...lda Hot water collection solenoid valve Magnetventil Hei wasserent nahme lectrovanne de pr l vement d eau chaude Electrov lvula toma de agua caliente Magneetventiel automatisch aftappen warm water Ele...

Page 30: ...la placa presente sobre el cable de alimentaci n Generalmente las m quinas est n predispuestas para una conexi n de estrella con neutro ELEKTRISCHE AANSLUITING Alvorens de machine op het elektricitei...

Page 31: ...r gua de deriva o B modificando as liga es indicadas no esquema ao lado Delta connection To change the connection from a star connection to a delta connection modify the connections shown in the diag...

Page 32: ...scht werden Auf dem Versorgungsklemmbrett A zwei Br cken hinzuf gen C die mitgeliefert werden und die Verbindungen sowohl auf dem Klemmbrett A als auch auf dem Klemmbrett B ndern wie es auf dem nebens...

Page 33: ...Cod WGA8003021000 Rev 06...

Reviews: