8
/
23
1: Configure the IP address, subnet mask, and gateway; the factory default IP of the device is static
IP 192.16.0.7
2: Configure web login password; factory default user name: admin password: admin
3: Add configuration serial port parameters; factory default: invalid inspection, 8 data bits, 1 stop
bit; network module is guest
In client mode, the server IP defaults to 192.168.0.201, where you can enter the domain name
address.
4: Configure serial port baud rate, local port, remote port
The factory default of the device is 9600BPS, 20108, 8234
It should be noted that the port IP can be modified, but the baud rate cannot be modified at will, but
only 9600BPS
5: Click here to save after setting all items.
Find the software interface of USR-K2
1. Set the IP address, subnet mask and gateway of the current network module, click after setting
2
Save it.
3 A very important point is that you should not change the baud rate arbitrarily. This is related to
the Wiegand conversion communication within the device, and Wiegand signals cannot be
transmitted after random modification. The factory default is 9600.
Click here
to find
equipment
3
,4
5
1
2
Click here
to open the
webpage