15
closing position), waiting for the door to close in place and digital
display“---”;
B. Abnormal state: Power-on, the door repeatedly switchs back and forth,
then set the P15 parameter as 02, when power on again, and then observe
whether it enters the normal state A.
C. Abnormal state: Power-on, the digital tube on the circuit board shows "H07".
When the door moves towards opening ,please refer to(3.1) and dial the open
direction dial switch(red) on the circuit board to the opposite direction, and
then observe whether it enters the normal state A.
Note: please do not block when learning closing position, otherwise the
blocking position will be regarded as the closing position!
4.2 Opening Debugging
A. Opening Angle: if the opening Angle is not enough, increase the value of
P13; if it is too large, decrease the value of P13 to reach the desired Angle.
B. Opening speed: adjust the value of P10, the larger the value, the faster the
speed, the smaller the slower speed.
C. Time of open and hold : When the door open in place, the time of
stopping at the position, and adjust the value of P04 (in seconds).
4.3.Closing Debugging
A. Closing speed: Adjust the value of P01, the larger the value, the faster the
speed, the smaller the slower;