S+S Regeltechnik THERMASGARD ALTM2-Q Operating Instructions, Mounting & Installation Download Page 2

D G F r

THERMASGARD

® 

ALTM 1

Maßzeichnung 

Dimensional drawing 

 

 

Plan coté 

Габаритный чертеж

ALTM 1

ohne Display 

without display 

sans écran 

без дисплея

mit Display 

with display 

avec écran 

с дисплеем

39

49

ø 4.3

64

64

43.3

14.8

M16x1.5

37.8

14.8

M16x1.5

15

4.3

42

15

4.3

42

 ~107

72

Maßzeichnung 

Dimensional drawing 

 

 

Plan coté 

Габаритный чертеж

ALTM 2

KL

M12x1.5

64

M12x1.5

64

39

49

ø 4.3

72

43.3

14.8

M16x1.5

 ~107

14.8

37.8

M16x1.5

ø 

6

15

50

15

KL

M12x1.5

64

M12x1.5

64

39

49

ø 4.3

72

43.3

14.8

M16x1.5

 ~107

14.8

37.8

M16x1.5

ø 

6

15

50

15

M12-Steckverbinder  

(optional auf Anfrage)

M12 connector  

(optional on request)

connecteur M12  

(en option et sur demande)

разъем M12  

(опционально по запросу)

39

49

ø 4.3

64

64

43.3

14.8

M16x1.5

37.8

14.8

M16x1.5

15

4.3

42

15

4.3

42

 ~107

72

ohne Display 

without display 

sans écran 

без дисплея

mit Display 

with display 

avec écran 

с дисплеем

High-performance encapsulation against  

vibration, mechanical stress and humidity

High-Performance-Verguss gegen Vibration, 

mechanischer Belastung und Feuchtigkeit

P S - P R O T EC T I O N

PERFEC T SENSOR PROTEC TION

Summary of Contents for THERMASGARD ALTM2-Q

Page 1: ...nge switching and active output F Notice d instruction Sonde de temp rature d applique pour conduites avec convertisseur y compris collier de serrage talonnable avec commutation multi gamme et sortie...

Page 2: ...5 KL M12x1 5 64 M12x1 5 64 39 49 4 3 72 43 3 14 8 M16x1 5 107 14 8 37 8 M16x1 5 6 15 50 15 M12 Steckverbinder optional auf Anfrage M12 connector optional on request connecteur M12 en option et sur dem...

Page 3: ...1 5 m andere L ngen und Mantelmaterialien z B PTFE oder Glasseide mit Stahlgeflecht optional auf Anfrage Sensorschutz ALTM2 Rohranleger aus Edelstahl V4A 1 4571 6 mm L 50 mm elektrischer Anschluss 0 1...

Page 4: ...UB f r 15 36 V DC Einspeisung und UB bzw GND als Masseleitung zu verwenden Werden mehrere Ger te von einer 24 V AC Spannung versorgt ist darauf zu achten dass alle positiven Betriebsspannungseing nge...

Page 5: ...e und Bedie nungsanleitung Abweichungen zur Katalogdarstellung sind nicht zus tz lich aufgef hrt und im Sinne des technischen Fortschritts und der ste tigen Verbesserung unserer Produkte m glich Bei V...

Page 6: ...materials e g PTFE or glass fibre with steel mesh available on request Sensor protection ALTM2 pipe feeder made of stainless steel V4A 1 4571 6 mm L 50 mm Electrical connection 0 14 1 5 mm via termin...

Page 7: ...utputs of field devices must be referenced to the same potential In case of reversed polarity at one field device a supply voltage short circuit would be caused by that device The consequential short...

Page 8: ...l only be used for their intended purpose Respective safety regulations issued by the VDE the states their control authorities the T V and the local energy supply company must be observed The buyer ha...

Page 9: ...t riaux de gaine par ex PTFE ou fibre de verre sous tresse m tallique en option sur demande Protection de capteur ALTM2 Sonde d applique pour conduites en acier inox V4A 1 4571 6 mm L 50 mm Raccordeme...

Page 10: ...nu il faut utiliser l entr e de tension de service UB pour l alimentation en 15 36 V cc et UB ou GND comme c ble de masse Si plusieurs appareils sont aliment s en 24V ca il faut veiller ce que toutes...

Page 11: ...pprovisionnement en nergie locales sont respecter L acheteur doit respecter les dispositions relatives la construction et la s curit et doit viter toutes sortes de risques Les d fauts et dommages r su...

Page 12: ...C 95 III EN 60 730 IP65 EN 60 529 T V S D 713139052 Tyr 1 ALTM2 IP65 EN 60 529 IP68 EN 60 529 CE EN 61326 2014 30 EU 36 x 15 x r THERMASGARD ALTM Rev 2022 V18 THERMASGARD ALTM 2 ALTM 2 Q WG01 Q ALTM...

Page 13: ...sible range 30 70 C c 0 10 0 UB 15 36 UB GND 24 Circuitry Circuitry 0 10V 0V GND 0 10V 0V GND Power supply AC 24V 0V DC 15 36V GND Circuitry 0 10V 0V GND V Power supply AC 24V 0V DC 15 36V GND THERMAS...

Page 14: ...r EMV VDE VDI DDC PLC 0 5 g 0 10 0 10 4 20 mA 4 20 4 VDE r ZVEI VDE EMV...

Page 15: ...rreurs et de modifications techniques Toutes les informations correspondent l tat de nos connaissances au moment de la publication Elles servent uniquement informer sur nos produits et leurs possibili...

Page 16: ...n side Display connector max min 10K Offset 12 3 1 2 4 5 3 ON Passive sensor Passive sensor UB 24 V AC DC Output 0 10 V UB GND Internal sensor optional Internal passive sensor optional DIP switches Me...

Reviews: