11 — English
MAiNTENANcE
WARNiNg:
When servicing, use only identical replacement parts.
Use of any other parts may create a hazard or cause
product damage.
WARNiNg:
Always wear eye protection with side shields marked to
comply with ANSI Z87.1. Failure to do so could result in
objects being thrown into your eyes and other possible
serious injuries.
gENERAL MAiNTENANcE
Avoid using solvents when cleaning plastic parts. Most
plastics are susceptible to damage from various types of
commercial solvents and may be damaged by their use. Use
clean cloths to remove dirt, dust, oil, grease, etc.
WARNiNg:
Do not at any time let brake fluids, gasoline, petroleum-
based products, penetrating oils, etc., come in contact
with plastic parts. Chemicals can damage, weaken or de-
stroy plastic which may result in serious personal injury.
REPLAciNg THE BULB
See Figure 13, page 14.
Turn off the unit and allow the bulb to cool
Rotate the lens cover counterclockwise. Remove lens
cover and lens.
Push bulb in slightly and turn it clockwise to release it
from bulb socket. Remove bulb
NOTE: The spring should remain attached to the worklight
as shown.
Place replacement bulb into bulb socket. Push bulb in
slightly and turn it counterclockwise to secure it.
Return the lens and secure the lens cover by turning it
counterclockwise until it is securely in place.
REPLAciNg THE 12V AdAPTOR fUSE
See Figure 14, page 14.
The 12 V adaptor contains a 250 V 10 Amp fuse to protect
the adaptor and charger from unexpected power surges.
To replace the fuse:
Remove the fuse cap from the top of the 12 V adaptor.
Replace old fuse with new one. If spring comes out, be
sure to reinsert it before replacing new fuse.
cAUTiON:
Do not use a higher rated fuse other than the specified
amperage. This could cause damage to the product.
Place fuse cap on top of fuse and thread back onto adap-
tor. Tighten securely.
Summary of Contents for YN600A
Page 35: ...22 English NOTES...