background image

2

 WARNING

 WARNING

 WARNING

The pump is not suited to discharge salt water, 

sewage, flammable, caustic or hazardous liquids. 

Please observe the max. temperature of the liquids 

to be discharged stated in the technical data.

Inside the pump, lubricants are used which may 

contaminate the liquids being discharged in case 

of any improper operation or damage of the device. 

The lubricants used are biologically degradable and 

nonhazardous to health.

During the entire process of installation, the device 

must not be connected to the electrical mains. The 

pump and the entire connection system have to be 

protected from frost.

INTENDED USE

INSTALLATION

 WARNING

Make sure the pump is disconnected from electric 

power supply before performing maintenance 

procedures.

MAINTENANCE

CLEANING THE PUMP HOUSING

Use a moist cloth to wipe down the pump housing. 

Allow to dry thoroughly before storing in a dry location 

that is protected from bad weather conditions.

 

Ensure all connections are leak free. Use a thread 

seal tape (sold separately ) or a suitable sealant on 

the connection thread

 

When tightening threaded connections, please 

do not apply excessive force which may cause 

damage.

 

When laying the connection pipes, you should 

 

Avoid inserting hands into the inlets/outlets of the 

water pump while it is connected to power.

 

Before using the water pump, always inspect it 

visually. Do not use the pump if it is cracked and/or 

damaged. 

 

The water pump has a built-in thermal protection 

overload switch. The water pump stops if an 

overload occurs. The motor restarts automatically 

after it has cooled down.

 

The pump must not be used when people are in the 

water.

 

Never work or perform maintenance on the pump 

without first making sure it has been disconnected 

from the mains power.

 

Pollution of the liquid could occur due to leakage of 

lubricants.

Important: 

Avoid inserting hands into the mouth of 

the pump if it is connected to the mains. The electrical 

connection must always be made in a dry area. Make 

sure that electrical connections are protected from 

inundations.

Protect the plug and the power cable from heat, oil or 

sharp edges.

 WARNING

The water pump together with associated pipework 

operate under pressure. Do not disconnect water 

pump or pipework until internal pressure has been 

released. Failure to do this could result in personal 

injury and damage to property.

 

A distinctive feature of this pump is that it can 

briefly operated (max. 4 min.) with liquids with a 

temperature up to 95°C (see Technical data).

 

RYOBI Submersible dirty water pumps are highly 

efficient electrical pumps for discharging clean or 

dirty water containing solids up to the maximum size 

specified in the technical details.

 

This pump is intended for discharging clean or dirty 

water containing solids up to the maximum size 

35mm

 

Typical applications for waste water submersible 

pumps are: Emptying ponds, tanks, storage tanks, 

and waste water pits, emergency drainage in the 

event of flood etc. This product is intended for 

household use only, not for extended continuous 

operation.

SYMBOLS DEFINITION ON THE PRODUCT

Summary of Contents for RSCD750

Page 1: ...RSCD750 750W CLEAN DIRTY SUMBERSIBLE PUMP...

Page 2: ...2 Pump base 3 Suction port 4 Floating switch 5 Cable of floating switch 6 Cable holder 7 Carry handle 8 Power cable 9 Pressure relief valve 10 Pump housing 11 Right angle adaptor 1 11 10 9 2 4 3 5 6 7...

Page 3: ...DESCRIPTION 30 30 100mm minimum PUSH START STOP A B C Fig 5 Fig 7 Fig 6 Fig 8 Fig 1 Fig 3 Fig 2 Fig 4...

Page 4: ...Important It is essential that you read the instructions in this manual before assembling operating and maintaining the product Subject to technical modification...

Page 5: ...ing surfaces dry clean and free from oil and grease Slippery handles and grasping surfaces do not allow for safe handling and control of the tool in unexpected situations Do not overreach Keep proper...

Page 6: ...a built in thermal protection overload switch The water pump stops if an overload occurs The motor restarts automatically after it has cooled down The pump must not be used when people are in the wate...

Page 7: ...om the adjuster to the float Fig 3 4 Manual mode when the float is manually secured at ON position the pump can draw down to a minimum level of 54mm at 0m delivery height Fig 4 HOW TO POSITION THE PUM...

Page 8: ...raulic part from sediments and dirt This can be done by counter flushing the unit with clean water using a hose to be connected through the pressure port of the pump To remove tenacious dirt the foot...

Page 9: ...is equipped with a purge which is used to evacuate the air Ensure that this purge is clean SPECIFICATIONS Rated Power Max Head Max Immersion Depth Max Water Flow Max Working Temp Max Particle Size Cab...

Page 10: ...clogged or kinked Remove possible congestion kink in the line Air penetrates into the pump body Start pump several times so that the entire air will be driven out Check valve non return valve if pres...

Page 11: ......

Page 12: ...ronic Industries Australia Pty Ltd 31 Gilby Road Mount Waverley VIC 3149 Melbourne Australia TechtronicIndustriesN Z Limited Unit C 70 Business Parade South Highbrook Auckland 2013 New Zealand Importe...

Reviews: