COMMON FAILURES AND TREATMENT

Malfunction

Possible cause

Elimination

The pump is not 

discharging any 

liquid, the motor is 

not running.

Thermal motor protection feature has 

triggered. (for information on operation with 

liquids > 50°C, see the note in Technical 

data).

Separate the pump from the electrical 

mains, allow the system to cool down, 

eliminate cause.

The min. suction level was fallen short of; 

Make sure that the minimum suction level is 

not fallen short of; if necessary, adjust floating 

switch properly or make sure that it can move 

freely; in the case of a defective floating switch,  

check the output hose is not blocked or crimped 

please contact customer service.

The capacitor is defective.

Please contact the customer service 

department.

The pump wheel is blocked.

Eliminate blocking of pump wheel.
Please contact the customer service 

department.

The motor is 

running, but 

the pump is not 

discharging any 

liquid.

The intake openings are clogged.

Remove possible congestion.

The pressure line is clogged or kinked.

Remove possible congestion / kink in the line.

Air penetrates into the pump body.

Start pump several times so that the entire 

air will be driven out.

Check valve (non-return valve), if present, 

is blocked or defective.

Eliminate blocking of the check valve 

(nonreturn valve) or replace, if damaged.

The pump stops 

after a short 

time of operation 

because the 

thermal motor 

protection feature 

has triggered.

Pump or intake openings are blocked by 

solids. 

Remove possible congestion.

Liquid is too viscous.

Pump may not be suitable for this liquid. If 

feasible, the liquid should be thinned.

Temperature of the liquid is too high.

Make sure that the temperature of the 

liquid being pumped does not exceed the 

max. admissible value.

Pump is running dry.

Eliminate causes of dry-running.

Intermittent 

or irregular 

operation.

Pump wheel obstructed by solid matters. Remove solids.

Mains voltage out of tolerance.

Make sure that mains voltage matches that 

indicated on the type plate.

Motor or pump wheel defective.

Please contact the customer service 

department.

The pump does 

not cut in or out.

Floating switch cannot move freely.

Floating switch defective.

Please contact the customer service 

department.

Summary of Contents for RSCD750

Page 1: ...RSCD750 750W CLEAN DIRTY SUMBERSIBLE PUMP...

Page 2: ...2 Pump base 3 Suction port 4 Floating switch 5 Cable of floating switch 6 Cable holder 7 Carry handle 8 Power cable 9 Pressure relief valve 10 Pump housing 11 Right angle adaptor 1 11 10 9 2 4 3 5 6 7...

Page 3: ...DESCRIPTION 30 30 100mm minimum PUSH START STOP A B C Fig 5 Fig 7 Fig 6 Fig 8 Fig 1 Fig 3 Fig 2 Fig 4...

Page 4: ...Important It is essential that you read the instructions in this manual before assembling operating and maintaining the product Subject to technical modification...

Page 5: ...ing surfaces dry clean and free from oil and grease Slippery handles and grasping surfaces do not allow for safe handling and control of the tool in unexpected situations Do not overreach Keep proper...

Page 6: ...a built in thermal protection overload switch The water pump stops if an overload occurs The motor restarts automatically after it has cooled down The pump must not be used when people are in the wate...

Page 7: ...om the adjuster to the float Fig 3 4 Manual mode when the float is manually secured at ON position the pump can draw down to a minimum level of 54mm at 0m delivery height Fig 4 HOW TO POSITION THE PUM...

Page 8: ...raulic part from sediments and dirt This can be done by counter flushing the unit with clean water using a hose to be connected through the pressure port of the pump To remove tenacious dirt the foot...

Page 9: ...is equipped with a purge which is used to evacuate the air Ensure that this purge is clean SPECIFICATIONS Rated Power Max Head Max Immersion Depth Max Water Flow Max Working Temp Max Particle Size Cab...

Page 10: ...clogged or kinked Remove possible congestion kink in the line Air penetrates into the pump body Start pump several times so that the entire air will be driven out Check valve non return valve if pres...

Page 11: ......

Page 12: ...ronic Industries Australia Pty Ltd 31 Gilby Road Mount Waverley VIC 3149 Melbourne Australia TechtronicIndustriesN Z Limited Unit C 70 Business Parade South Highbrook Auckland 2013 New Zealand Importe...

Reviews: