INSTALLATION OF THE PRESSURE LINE

The pressure line conveys the liquids to be discharged 

from the pump to the point of withdrawal. To avoid 

dynamic flow losses, one should use a pressure line 

having at least the same diameter as the water outlet (1) 

of the pump.

make sure that the pump is not exposed to any 

form of weight, vibration or tension. Moreover, the 

connection lines must not contain any kinks.

 WARNING

 WARNING

Please make sure that the pump will cut out as soon

as the water level decreases and the floating swith 

has reached the cut-out level.

Also it must be made sure that the floating switch 

can move freely.

 The pump MUST be attended when used in this mode 

as the motor receives no cooling and can over heat. 

1.  Screw the connection adaptor (10) into the pump 

outlet.

2.  Screw the connection port into the connection 

adaptor.

3.  Fix a hose to the combination nipple, use a hose 

clamp to secure the hose.

STATIONARY INSTALLATION

If the unit is used in a stationary installation, rigid pipes 

have proven to be the ideal choice for the pressure 

lines. In this type of installation, we recommend that 

you incorporate a check valve (non-return valve) in the 

pressure line immediately following the pump outlet 

so that no liquid will flow back after the pump cuts out. 

To facilitate maintenance work, we also recommend 

the installation of a stop cock valve downstream of the 

pump and check valve. This arrangement is beneficial 

in that closing the stop cock will prevent the pressure 

line from running dry after the disassembly of the pump.

HOW TO SET FLOAT SWITCH

The pump is fitted with a float switch, which controls 

how the pump switches on and switches off.

1.  When the float switch is about 30° higher than 

horizontal (start up level) or above the handle, the 

pump will turn ‘on’ and operate. 

(Fig. 1)

2.  When the float switch is 30° lower than the 

horizontal or below the handle, the pump will turn 

‘off’. 

(Fig. 2)

3.  To set the pump to switch off at a lower water level, 

insert the float switch cable into the adjuster Note: 

There must be a minimum of 100mm of cable from 

the adjuster to the float. 

(Fig. 3)

4.  Manual mode: when the float is manually secured at 

ON position, the pump can draw down to a minimum 

level of 54mm (at 0m delivery height) 

(Fig. 4)

HOW TO POSITION THE PUMP

 

When positioning the pump, please make sure that 

the max. immersion depth indicated in the technical 

data will not be exceeded.

 

Likewise, please make sure that the minimum 

selfpriming level is not fallen short of. If everything 

is properly set, the water level may decrease 

down to the minimum suction level once the pump 

is operating. Please position the pump on solid 

ground. Avoid placing it on lose stones or sand.

 

For Clean water, the pump can be positioned at the 

bottom after setting to Clean water mode (Fig

.

 5-8)

 

To position, lift up or carry the pump, please use 

only the carrying handle(7).

 

If required for lowering or raising the pump, you 

must connect a suitable lowering rope to the 

carrying handle. Do NOT lift pump using the hose, 

power cord or float cable.

ELECTRICAL CONNECTION

 

The unit is equipped with a power connection cable 

and a plug. It must only be replaced by qualified 

staff to avoid any danger. Please do not use the 

power cable to carry the pump, and do not use this 

cable to pull off the plug from the socket, either. 

Protect the power cable and mains plug from heat, 

oil or sharp edges.

 

The values stated in the technical details have 

to correspond to the mains voltage. The person 

responsible for the installation has to make sure that 

the electrical connection is earthed in compliance 

with the applicable standards.

 

The electrical connection has to be equipped with 

a highly sensitive residual current circuitbreaker 

(FIswitch) : Δ = 30 mA.

 

If extension cables are used, their cross-section 

must not be smaller than that of rubbersheathed 

cables of the H07RN-F (3 x 1,0 mm²) short code.

The mains socket and the plugand-socket elements 

have to be in splash water-proof design.

HOW TO SWITCH BETWEEN CLEAN AND DIRTY 

WATER APPLICATION

1.  When you want to switch between CLEAN and 

DIRTY application, put down the pump base, and 

find the arrow direction. (Fig.5).

2.  Pull out the transfer valve out of the base.  (Fig. 6).
3.  Spinning 180 to the arrow direction sign of the 

requested application. (Fig. 7)

4.  Press down the transfer valve to lock the pump 

base.  (Fig. 8)  

Summary of Contents for RSCD750

Page 1: ...RSCD750 750W CLEAN DIRTY SUMBERSIBLE PUMP...

Page 2: ...2 Pump base 3 Suction port 4 Floating switch 5 Cable of floating switch 6 Cable holder 7 Carry handle 8 Power cable 9 Pressure relief valve 10 Pump housing 11 Right angle adaptor 1 11 10 9 2 4 3 5 6 7...

Page 3: ...DESCRIPTION 30 30 100mm minimum PUSH START STOP A B C Fig 5 Fig 7 Fig 6 Fig 8 Fig 1 Fig 3 Fig 2 Fig 4...

Page 4: ...Important It is essential that you read the instructions in this manual before assembling operating and maintaining the product Subject to technical modification...

Page 5: ...ing surfaces dry clean and free from oil and grease Slippery handles and grasping surfaces do not allow for safe handling and control of the tool in unexpected situations Do not overreach Keep proper...

Page 6: ...a built in thermal protection overload switch The water pump stops if an overload occurs The motor restarts automatically after it has cooled down The pump must not be used when people are in the wate...

Page 7: ...om the adjuster to the float Fig 3 4 Manual mode when the float is manually secured at ON position the pump can draw down to a minimum level of 54mm at 0m delivery height Fig 4 HOW TO POSITION THE PUM...

Page 8: ...raulic part from sediments and dirt This can be done by counter flushing the unit with clean water using a hose to be connected through the pressure port of the pump To remove tenacious dirt the foot...

Page 9: ...is equipped with a purge which is used to evacuate the air Ensure that this purge is clean SPECIFICATIONS Rated Power Max Head Max Immersion Depth Max Water Flow Max Working Temp Max Particle Size Cab...

Page 10: ...clogged or kinked Remove possible congestion kink in the line Air penetrates into the pump body Start pump several times so that the entire air will be driven out Check valve non return valve if pres...

Page 11: ......

Page 12: ...ronic Industries Australia Pty Ltd 31 Gilby Road Mount Waverley VIC 3149 Melbourne Australia TechtronicIndustriesN Z Limited Unit C 70 Business Parade South Highbrook Auckland 2013 New Zealand Importe...

Reviews: