OPERATION

OVERLOAD PROTECTION

This compressor has a thermal overload device. If
the motor gets too hot, the thermal overload device
cuts the power which prevents damage to the
motor.

If the thermal overload device operates, let the
motor cool down for 5 minutes and push the reset
button.

If you start the compressor and the overload cutout
operates again, stop the compressor and
disconnect from the power supply and have your
compressor examined by a qualified service agent.

SWITCHING ON AND OFF

WARNING.

Switching On & Off must be

done using the On/Off switch mounted
on the compressor. Switching the
compressor Off at the mains supply can
damage the motor and will invalidate the
guarantee.

Before switching on the power supply to the
compressor check that the On/Off switch is in the
Off position (pressed in) (Fig.6).

Check that the air outlet pressure regulator is
closed (Fig 7).

Check that the drain valve is closed (Fig.8).

Connect the compressor to a suitable 16A mains
supply. Switch on the compressor by pulling up the
On/Off switch (Fig.9). The compressor will now
start.

When the air receiver tank is pressurised to its
working capacity the compressor will automatically
switch off. When the compressor switches off there
will be the sound of leaking air while the pressure
regulating system is depressurised, this will last for
only a few seconds and is quite normal. Check all
valves and regulators for leaks. Note during
extended periods of use the air receiver tank
supply tube will become hot.

WARNING.

Always ensure the switch is

in the OFF position (pressed in) and
the pressure gauge reads zero before
changing air tools or disconnecting the
hose from the air outlet. Failure to do so
could result in possible serious personal
injury.

Fig. 6

Fig. 7

Fig. 8

Fig. 9

Press down

for OFF

Pull up for

ON

Summary of Contents for RC-3100B

Page 1: ... enjoy years of safe reliable service SPECIFICATIONS Voltage 230V 50Hz R Intermittent duty S3 75 ated power 2 2kW 3 0HP Receiver capacity 100l Type Oil lubricated Free air delivery FAD 365l min Oil type SAE 30 Oil capacity 500ml CFM 12 9 Working pressure 10bar 145psi No load speed 1375min 1 Sound pressure level LpA71 5dB A k 3dB A Sound power level LWA91 5dB A k 3dB A Net weight 59 2kg THANK YOU F...

Page 2: ...gs and safety instructions in this manual and on the product Ensure that this compressor is disconnected from the mains supply when not in use and the air receiver fully discharged before servicing lubricating or making adjustments and when changing accessories Always switch ON and OFF using the ON OFF switch on the compressor before switching OFF at the mains supply WARNING When spraying paint or...

Page 3: ...fe Never weld or drill holes in the air tanks Only use recommended parts To avoid the risk of bursting only hoses with a rated pressure of 10 bar or more should be used Never attempt to re pair faulty hoses Avoid kinking or trapping the air hose Always replace faulty hoses never attempt a repair if a leak is detected Make sure the hose is free of obstructions or snags Entangled or snarled hoses ca...

Page 4: ... with ANSI Z87 1 c Additional safety protection will be required in some environments For example the working area may include exposure to a noise level which can lead to hearing damage The employer and user must ensure that any necessary hearing protection is provided and used by the operator and others in the work area Some environments will require the use of head protection equipment When requ...

Page 5: ...ct is powered by a precision built electric motor It should be connected to a power supply that is 230 V AC only normal household current 50 Hz Do not operate this product on direct current DC A substantial voltage drop will cause a loss of power and the motor will overheat If the product does not operate when plugged into an outlet double check the power supply GROUNDING INSTRUCTIONS This product...

Page 6: ... regulated 5 Transportation handle 6 Air outlet pressure gauge 7 Air receiver pressure gauge 8 Rubber foot x 2 9 Wheel x 2 10 Drain valve 11 Air receiver tank 12 Oil drain plug 13 Dipstick 14 Air filter 15 Safety valve 16 Air outlet pressure regulator lock ring DESCRIPTION 11 2 3 8 9 4 6 7 5 14 13 10 1 12 15 16 ...

Page 7: ...TS Belt driven compressor Wheels x 2 Wheel fixings bolt nut x 2 Rubber foot x 2 Rubber foot fixings bolt nut x 2 Dipstick Operator s Manual WARNING If any parts are damaged or missing do not operate this product until the parts are replaced Use of this product with damaged or missing parts could result in serious personal injury WARNING Do not connect to power supply until assembly is complete Fai...

Page 8: ...ease all tank air pressure before removing the dipstick Be sure the air vent in dipstick Fig 3 is free from debris If air vent is blocked pressure can build in crankcase causing damage to the compressor and possible personal injury Remove the dipstick by twisting it upwards by hand Fill the compressor pump with an air compressor oil such as SAE 30 non detergent API CG CD Heavy Duty oil at slow int...

Page 9: ... used play an important role in the operation of this product Wiring intended for lights cannot properly carry an air compressor motor and wire that is heavy enough for a short distance may be insufficient for a greater distance Before using this product verify your receptacle is wired appropriately for air compressor use and the length and gauge of any extension cord used is sufficient to carry t...

Page 10: ...ion pressed in Fig 6 Check that the air outlet pressure regulator is closed Fig 7 Check that the drain valve is closed Fig 8 Connect the compressor to a suitable 16A mains supply Switch on the compressor by pulling up the On Off switch Fig 9 The compressor will now start When the air receiver tank is pressurised to its working capacity the compressor will automatically switch off When the compress...

Page 11: ...at the same time observing the air outlet pressure gauge until the pressure gauge reads the minimum pressure for the accessory Fine adjustments to the air pressure can be made until the accessory is working at its optimum performance When the correct operating air pressure has been set the air outlet pressure regulator can be locked by tightening the locking ring Fig 12 Do not exceed the maximum r...

Page 12: ...ondensation Carefully undo the drain valve nut anti clockwise until you hear a hissing noise this is the reservoir depressurising Fig 15 When the gauge indicates zero and the hissing has stopped tighten the drain valve nut again OIL CHANGING Replace the oil after the first 100 hours of operation and every 300 hours subsequently Remember to check the oil level at regular intervals For changing the ...

Page 13: ...emove the securing bolt and pull the filter from the compressor Fig 16 Unclip the front and rear of the filter and pull out the filter element Fig 17 Clean the filter using a soft brush If necessary the filter can be carefully cleaned in warm soapy water Rinse and let the filter dry completely before refitting If the filter or filter element is damaged you must replace it Reassemble the filter and...

Page 14: ... it is advisable to give the compressor a thorough clean This should include the removal of all fitted accessories Do not use any solvents as these can damage plastic parts Only use a clean cloth dampened with warm soapy water Any metal parts should be given a wipe with a light machine oil to prevent rusting WARNING Do not at any time let brake fluids gasoline petroleum based products penetrating ...

Page 15: ...ghten if necessary Switch off and wait approx 5 minutes Press the reset button and switch on again Contact your nearest service agent Return the machine to your nearest service agent Open drain valve to expel air Compressor should start again when pressure reduces Drain receiver completely of air Remove the valve end plug Carefully clean the valve seat and the gasket Reassemble Replace regulator R...

Page 16: ...rdous Voltage Disconnect from power source before servicing Do not use in damp conditions Hot Surface To reduce the risk of injury or damage avoid contact with any hot surface Enclosure Alert Do not operate the portable compressor with the doors or enclosure open Unexpected Starting The compressor may start without warning Recycle Symbol Waste electrical products should not be disposed of with hou...