background image

4

IMPORTANT SAFETY INSTRUCTIONS

c)

Keep bystanders, children, and visitors
away while operating an air compressor.

Distractions can cause you to lose control.

d)

Operate air compressor in an open area at
least 50cm away from any wall or object that
could restrict the flow of fresh air to
ventilation openings.

2) ELECTRICAL SAFETY

a)

Avoid body contact with grounded surfaces
such as pipes, radiators, ranges, and
refrigerators.

There is an increased risk of

electric shock if your body is grounded.

b)

Don’t expose air compressors to rain or wet
conditions.

Water entering an air compressor

will increase the risk of electric shock.

c)

Do not abuse the cord. Never use the cord
to carry the air compressor or pull the plug
from an outlet. Keep cord away from heat,
oil, sharp edges, or moving parts. Replace
damaged cords immediately.

Damaged cords

increase the risk of electric shock.

d)

When operating an air compressor outside,
use an outdoor extension cord marked
“W-A” or “W”.

These cords are rated for

outdoor use and reduce the risk of electric
shock.

3) PERSONAL SAFETY

a)

Eye protection which conforms to ANSI
specifications and provides protection
against flying particles both from the
FRONT and SIDE should ALWAYS be worn
by the operator and others in the work area
when loading, operating, or servicing this
product.

Eye protection is required to guard

against flying fasteners and debris, which could
cause severe eye injury.

b)

The employer and/or user must ensure that
proper eye protection is worn.

We

recommend a Wide Vision Safety Mask for use
over eyeglasses or standard safety glasses
that provide protection against flying particles
both from the front and side. Always use eye
protection which is marked to comply with
ANSI Z87.1.

c)

Additional safety protection will be required
in some environments.

For example, the

working area may include exposure to a noise

level which can lead to hearing damage. The
employer and user must ensure that any
necessary hearing protection is provided and
used by the operator and others in the work
area. Some environments will require the use
of head protection equipment. When required,
the employer and user must ensure that head
protection marked to comply with ANSI Z89.1 is
used.

d)

Stay alert, watch what you are doing, and
use common sense when operating the air
compressor. Do not use product while tired
or under the influence of drugs, alcohol, or
medication.

A moment of inattention while

operating an air compressor may result in
serious personal injury.

e)

Dress properly. Do not wear loose clothing
or jewellery. Contain long hair. Keep your
hair, clothing, and gloves away from moving
parts.

Loose clothes, jewellery, or long hair can

be caught in moving parts.

f)

Do not overreach. Keep proper footing and
balance at all times.

Proper footing and

balance enables better control of the product in
unexpected situations.

g)

Use safety equipment. Always wear eye
protection.

Dust mask, nonskid safety shoes,

hard hat, or hearing protection must be used
for appropriate conditions.

h)

Do not use on a ladder or unstable support.

Stable footing on a solid surface enables better
control of the air compressor in unexpected
situations.

4) AIR COMPRESSOR USE AND CARE

a)

Do not exceed the pressure rating of any
component in the system.

b)

Protect material lines and air lines from
damage or puncture.

Keep hose and power

cord away from sharp objects, chemical spills,
oil, solvents, and wet floors.

c)

Check hoses for weak or worn condition
before each use, making certain all
connections are secure.

Do not use if defect

is found. Purchase a new hose or notify an
authorized service center for examination or
repair.

Summary of Contents for RC-3100B

Page 1: ... enjoy years of safe reliable service SPECIFICATIONS Voltage 230V 50Hz R Intermittent duty S3 75 ated power 2 2kW 3 0HP Receiver capacity 100l Type Oil lubricated Free air delivery FAD 365l min Oil type SAE 30 Oil capacity 500ml CFM 12 9 Working pressure 10bar 145psi No load speed 1375min 1 Sound pressure level LpA71 5dB A k 3dB A Sound power level LWA91 5dB A k 3dB A Net weight 59 2kg THANK YOU F...

Page 2: ...gs and safety instructions in this manual and on the product Ensure that this compressor is disconnected from the mains supply when not in use and the air receiver fully discharged before servicing lubricating or making adjustments and when changing accessories Always switch ON and OFF using the ON OFF switch on the compressor before switching OFF at the mains supply WARNING When spraying paint or...

Page 3: ...fe Never weld or drill holes in the air tanks Only use recommended parts To avoid the risk of bursting only hoses with a rated pressure of 10 bar or more should be used Never attempt to re pair faulty hoses Avoid kinking or trapping the air hose Always replace faulty hoses never attempt a repair if a leak is detected Make sure the hose is free of obstructions or snags Entangled or snarled hoses ca...

Page 4: ... with ANSI Z87 1 c Additional safety protection will be required in some environments For example the working area may include exposure to a noise level which can lead to hearing damage The employer and user must ensure that any necessary hearing protection is provided and used by the operator and others in the work area Some environments will require the use of head protection equipment When requ...

Page 5: ...ct is powered by a precision built electric motor It should be connected to a power supply that is 230 V AC only normal household current 50 Hz Do not operate this product on direct current DC A substantial voltage drop will cause a loss of power and the motor will overheat If the product does not operate when plugged into an outlet double check the power supply GROUNDING INSTRUCTIONS This product...

Page 6: ... regulated 5 Transportation handle 6 Air outlet pressure gauge 7 Air receiver pressure gauge 8 Rubber foot x 2 9 Wheel x 2 10 Drain valve 11 Air receiver tank 12 Oil drain plug 13 Dipstick 14 Air filter 15 Safety valve 16 Air outlet pressure regulator lock ring DESCRIPTION 11 2 3 8 9 4 6 7 5 14 13 10 1 12 15 16 ...

Page 7: ...TS Belt driven compressor Wheels x 2 Wheel fixings bolt nut x 2 Rubber foot x 2 Rubber foot fixings bolt nut x 2 Dipstick Operator s Manual WARNING If any parts are damaged or missing do not operate this product until the parts are replaced Use of this product with damaged or missing parts could result in serious personal injury WARNING Do not connect to power supply until assembly is complete Fai...

Page 8: ...ease all tank air pressure before removing the dipstick Be sure the air vent in dipstick Fig 3 is free from debris If air vent is blocked pressure can build in crankcase causing damage to the compressor and possible personal injury Remove the dipstick by twisting it upwards by hand Fill the compressor pump with an air compressor oil such as SAE 30 non detergent API CG CD Heavy Duty oil at slow int...

Page 9: ... used play an important role in the operation of this product Wiring intended for lights cannot properly carry an air compressor motor and wire that is heavy enough for a short distance may be insufficient for a greater distance Before using this product verify your receptacle is wired appropriately for air compressor use and the length and gauge of any extension cord used is sufficient to carry t...

Page 10: ...ion pressed in Fig 6 Check that the air outlet pressure regulator is closed Fig 7 Check that the drain valve is closed Fig 8 Connect the compressor to a suitable 16A mains supply Switch on the compressor by pulling up the On Off switch Fig 9 The compressor will now start When the air receiver tank is pressurised to its working capacity the compressor will automatically switch off When the compress...

Page 11: ...at the same time observing the air outlet pressure gauge until the pressure gauge reads the minimum pressure for the accessory Fine adjustments to the air pressure can be made until the accessory is working at its optimum performance When the correct operating air pressure has been set the air outlet pressure regulator can be locked by tightening the locking ring Fig 12 Do not exceed the maximum r...

Page 12: ...ondensation Carefully undo the drain valve nut anti clockwise until you hear a hissing noise this is the reservoir depressurising Fig 15 When the gauge indicates zero and the hissing has stopped tighten the drain valve nut again OIL CHANGING Replace the oil after the first 100 hours of operation and every 300 hours subsequently Remember to check the oil level at regular intervals For changing the ...

Page 13: ...emove the securing bolt and pull the filter from the compressor Fig 16 Unclip the front and rear of the filter and pull out the filter element Fig 17 Clean the filter using a soft brush If necessary the filter can be carefully cleaned in warm soapy water Rinse and let the filter dry completely before refitting If the filter or filter element is damaged you must replace it Reassemble the filter and...

Page 14: ... it is advisable to give the compressor a thorough clean This should include the removal of all fitted accessories Do not use any solvents as these can damage plastic parts Only use a clean cloth dampened with warm soapy water Any metal parts should be given a wipe with a light machine oil to prevent rusting WARNING Do not at any time let brake fluids gasoline petroleum based products penetrating ...

Page 15: ...ghten if necessary Switch off and wait approx 5 minutes Press the reset button and switch on again Contact your nearest service agent Return the machine to your nearest service agent Open drain valve to expel air Compressor should start again when pressure reduces Drain receiver completely of air Remove the valve end plug Carefully clean the valve seat and the gasket Reassemble Replace regulator R...

Page 16: ...rdous Voltage Disconnect from power source before servicing Do not use in damp conditions Hot Surface To reduce the risk of injury or damage avoid contact with any hot surface Enclosure Alert Do not operate the portable compressor with the doors or enclosure open Unexpected Starting The compressor may start without warning Recycle Symbol Waste electrical products should not be disposed of with hou...

Page 17: ...17 NOTES ...

Page 18: ...18 NOTES ...

Page 19: ...19 NOTES ...

Page 20: ......

Reviews: