Depth Measurement When Using the Sonde
Once the S
ONDE
has been located, the depth can then be found. Refer to the figure below for a reference.
Start by moving the R
ECEIVER
along the path behind the S
ONDE
with the antenna in line with the S
ONDE
and
find a NULL between the PEAK ghost signals. Mark this point (A). Then move the R
ECEIVER
along the path
in front of the S
ONDE
and find another NULL. Mark this point (B). Next, measure the distance between these
two points. The depth of the pipe is 0.7 times the distance between the two points.
The 8879 is specially designed to measure the S
ONDE
depth digitally. To use this feature, the R
ECEIVER
must
be placed in the position shown in the diagram above. The R
ECEIVER
antenna must be in line with the
S
ONDE
. The R
ECEIVER
must also be in the S
ONDE
mode. Locate the S
ONDE
as described previously. When
the S
ONDE
has been located, press the DEPTH button. The LCD display will indicate dEP, SON and display
the depth of the S
ONDE
in feet or meters.
20