12
MOBILE AND WORKSHOP SERIES OPERATION MANUAL
October 2018 | Version: v1-0
START UP
OPERATION
Functional Tests and Re-testing
1. Check all bolts and screws
a) We strongly recommend after the initial test run and before commencing normal production, inspect and tighten
all the bolts/screws. Especially, those on movable components.
b) Please check and tighten all the bolts/screws every two or three days within the first two weeks.
2.
Check the machine carefully before operating
a) Check the power source is connected correctly to the incoming power terminal.
b) Check the machine is clean and without any other article on the machine.
3.
The function of safety equipment shall be tested before starting the machine.
Emergency stop
—actuate the push button, the motor power should shut down.
4.
The function of electrical equipment should be tested per half year normally, particularly the emergency push button.
5.
Where a portion of the machine and its associated equipment is changed or modified, tests should be re-verified and retested,
such as continuity test of the protective bonding circuit, insulation resistance tests, voltage tests, protection against residual
voltage and functional tests.
6.
Make sure the "PE" terminal is properly connected and the machine is grounded before turning on the main power.
7.
Check for any abnormal noise!
8.
All identified numbers on electrical wires must be correct, check if all wire terminals are properly tightened.
9.
Turn on the main isolator (NFB: No-fuse Breaker) power source to the main cabinet, check if the voltage is correct on the NFB
of main control panel and sub control panel.
Hydraulic System
Prior to filling the machine with hydraulic oil, the oil tank should be checked for cleanliness.
Remove the Fill / Vent cap. It is recommended to pump the oil into the tank through a 20 μ filter because new oil in drums is not pure.
The oil should reach the oil level mark.
On the initial fill ensure the suction strainer of the hydraulic pump must be completely submerged in oil, otherwise air will be drawn in
and cause oil foaming.
RY20C & RY32C Oil Tank
RY20CB & RY32CB Oil Tank